Service Reconfiguration (Nomadic ONT) (Frankfurt)
ID | Test Case Name | Status |
---|---|---|
D1 | PENDING | |
D2 | PENDING | |
D3 | PENDING | |
D4 | HSIA Service Activation and Service Status Change Notification (after relocation) | PENDING |
D5 | NOT TESTED |
CPE PNF Re-registration
Test Case ID | D1 |
---|---|
Test Case Name | CPE PNF Re-registration |
Description | CPE PNF changes location and re-attaches the network in a different OLT. ONAP detects re-location and re-registers the CPE PNF. |
Release | Frankfurt (6.0.0) |
Preconditions | - BBS E2E service instance and CPE PNF resource object have been created in AAI by SO |
Testing Steps |
|
Expected Results |
|
Actual Results | unauthenticated.VES_PNFREG_OPUTPUT[
"{\"event\":{\"commonEventHeader\":{\"startEpochMicrosec\":1555076831049,\"eventId\":\"registration_1555076831049\",\"internalHeaderFields\":{\"collectorTimeStamp\":\"Fri, 04 12 2019 04:04:27 UTC\"},\"eventType\":\"pnfRegistration\",\"priority\":\"Normal\",\"version\":\"4.0.1\",\"reportingEntityName\":\"VESMapper\",\"sequence\":0,\"domain\":\"pnfRegistration\",\"lastEpochMicrosec\":1555076831049,\"eventName\":\"pnfRegistration\",\"vesEventListenerVersion\":\"7.0.1\",\"sourceName\":\"Huawei-HWTCC01B7503\"},\"pnfRegistrationFields\":{\"unitType\":\"\",\"serialNumber\":\"HWTCC01B7503\",\"additionalFields\":{\"remote-id\":\"AC9.0234.0338\",\"attachment-point\":\"167772165-5-2\",\"cvlan\":\"11\",\"svlan\":\"101\"},\"pnfRegistrationFieldsVersion\":\"2.0\",\"manufactureDate\":\"\",\"modelNumber\":\"\",\"lastServiceDate\":\"\",\"unitFamily\":\"\",\"vendorName\":\"Huawei\",\"oamV4IpAddress\":\"\",\"oamV6IpAddress\":\"\",\"softwareVersion\":\"v2\"}}}"
] unauthenticated.PNF_UPDATE[
"{\"additionalFields\":{\"remote-id\":\"AC9.0234.0338\",\"attachment-point\":\"167772165-5-2\",\"cvlan\":\"11\",\"svlan\":\"101\"},\"correlationId\":\"Huawei-HWTCC01B7503\"}"
] BBSep uS log2019-04-12 16:13:23.194 TRACE 1 --- [ctor-http-nio-8] .u.ReRegistrationDmaapConsumerJsonParser : Event from DMaaP to be parsed:
{"additionalFields":{"remote-id":"AC9.0234.0338","attachment-point":"167772165-5-2","cvlan":"11","svlan":"101"},"correlationId":"Huawei-HWTCC01B7503"}
2019-04-12 16:13:23.195 DEBUG 1 --- [ctor-http-nio-8] o.o.b.e.p.p.ReRegistrationPipeline : Processing Step: Retrieve PNF. Url: (/aai/v14/network/pnfs/pnf/Huawei-HWTCC01B7503?depth=all)
2019-04-12 16:13:23.195 INFO 1 --- [ctor-http-nio-8] o.o.b.e.p.tasks.AaiClientTaskImpl : Executing task (PNF Retrieval) for retrieving PNF object
2019-04-12 16:13:23.195 DEBUG 1 --- [ctor-http-nio-8] o.o.b.e.p.utilities.AaiReactiveClient : Will issue Reactive GET request to URL (/aai/v14/network/pnfs/pnf/Huawei-HWTCC01B7503?depth=all) for object (org.onap.bbs.event.processor.model.PnfAaiObject)
2019-04-12 16:13:23.197 DEBUG 1 --- [ctor-http-nio-8] o.o.b.e.p.utilities.AaiReactiveClient : Request: GET https://aai.onap:8443/aai/v14/network/pnfs/pnf/Huawei-HWTCC01B7503?depth=all
2019-04-12 16:13:23.197 DEBUG 1 --- [ctor-http-nio-8] o.o.b.e.p.utilities.AaiReactiveClient : X-FromAppId=bbs
2019-04-12 16:13:23.198 DEBUG 1 --- [ctor-http-nio-8] o.o.b.e.p.utilities.AaiReactiveClient : Accept=application/json
2019-04-12 16:13:23.198 DEBUG 1 --- [ctor-http-nio-8] o.o.b.e.p.utilities.AaiReactiveClient : Authorization=Basic QUFJOkFBSQ==
2019-04-12 16:13:23.198 DEBUG 1 --- [ctor-http-nio-8] o.o.b.e.p.utilities.AaiReactiveClient : Content-Type=application/json
2019-04-12 16:13:23.198 DEBUG 1 --- [ctor-http-nio-8] o.o.b.e.p.utilities.AaiReactiveClient : Real-Time=true
2019-04-12 16:13:23.198 DEBUG 1 --- [ctor-http-nio-8] o.o.b.e.p.utilities.AaiReactiveClient : X-TransactionId=9999
2019-04-12 16:13:23.309 DEBUG 1 --- [ctor-http-nio-8] o.o.b.e.p.utilities.AaiReactiveClient : Response status 200 OK
2019-04-12 16:13:23.311 DEBUG 1 --- [ctor-http-nio-8] o.o.b.e.p.utilities.AaiReactiveClient : Response body
{"pnf-name":"Huawei-HWTCC01B7503","pnf-id":"4fca7530-062e-4f8a-9404-496832555c29","equip-type":"","equip-vendor":"Huawei","equip-model":"","sw-version":"v2","in-maint":false,"serial-number":"HWTCC01B7503","resource-version":"1555083285880","nf-role":"","relationship-list":{"relationship":[{"related-to":"service-instance","relationship-label":"org.onap.relationships.inventory.ComposedOf","related-link":"/aai/v14/business/customers/customer/BBSCustomer/service-subscriptions/service-subscription/BBS_E2E_Service/service-instances/service-instance/03b92492-c5c0-487a-b414-d5427ab6f041","relationship-data":[{"relationship-key":"customer.global-customer-id","relationship-value":"BBSCustomer"},{"relationship-key":"service-subscription.service-type","relationship-value":"BBS_E2E_Service"},{"relationship-key":"service-instance.service-instance-id","relationship-value":"03b92492-c5c0-487a-b414-d5427ab6f041"}],"related-to-property":[{"property-key":"service-instance.service-instance-name","property-value":"BBS_E2E_Service"}]}]}}
2019-04-12 16:13:23.312 WARN 1 --- [ctor-http-nio-8] o.o.b.e.p.p.ReRegistrationPipeline : PNF Huawei-HWTCC01B7503 does not have any logical-links bridged. Stop further processing |
Conclusion (Pass/Fail) | |
Testing Lab | |
Testing Date | |
Tester Name |
HSIA Service Reconfiguration
Test Case ID | D2 |
---|---|
Test Case Name | HSIA Service Reconfiguration |
Description | |
Release | Frankfurt (6.0.0) |
Preconditions | |
Testing Steps | |
Expected Results | |
Actual Results | |
Conclusion (Pass/Fail) | |
Testing Lab | |
Testing Date | |
Tester Name |
CPE Authentication (after relocation)
Test Case ID | D3 |
---|---|
Test Case Name | CPE Authentication (after relocation) |
Description | |
Release | Frankfurt (6.0.0) |
Preconditions | |
Testing Steps | |
Expected Results | |
Actual Results | |
Conclusion (Pass/Fail) | |
Testing Lab | |
Testing Date | |
Tester Name |
HSIA Service Activation and Service Status Change Notification (after relocation)
Test Case ID | D4 |
---|---|
Test Case Name | HSIA Service Activation and Service Status Change Notification (after relocation) |
Description | |
Release | Frankfurt (6.0.0) |
Preconditions | |
Testing Steps | |
Expected Results | |
Actual Results | |
Conclusion (Pass/Fail) | |
Testing Lab | |
Testing Date | |
Tester Name |
CPE power cycle vs CPE re-registration
Test Case ID | D5 |
---|---|
Test Case Name | CPE power cycle vs CPE re-registration |
Description | The customer powers off the CPE and, after some time, powers it on. The CPE registration message (if any) coming from the Access SDN M&C must not be treated as a PNF re-registration in ONAP |
Release | Frankfurt (6.0.0) |
Preconditions | |
Testing Steps | |
Expected Results | |
Actual Results | |
Conclusion (Pass/Fail) | NOT TESTED |
Testing Lab | |
Testing Date | |
Tester Name |