---TEST STATUS for Dublin Release ----

Use Case 1:

Event-driven bulk transfer of monitoring data from an xNF to ONAP/DCAE. A micro-service will listen for 'FileReady' VES events sent from an xNF via the VES collector. Once files become available the collector micro-service will fetch them using protocol such as FTPES or SFTP. The collected data files are published internally on a DMaaP Data Router (DR) feed.  A File Consumer node which is a simulated PM file subscriber that subscribe to Data Router feed and receive PM files.





Use Case 2:

Event-driven bulk transfer of monitoring data from an xNF to ONAP/DCAE. A micro-service will listen for 'FileReady' VES events sent from an xNF via the VES collector. Once files become available the collector micro-service will fetch them using protocol such as FTPES or SFTP. The collected data files are published internally on a DMaaP Data Router (DR) feed.  The PM mapper receives the files by subscribing to a Data Router feed. The 3GPP PM Mapper micro-service will extract selected (filtered) measurements from a 3GPP XML file and publish them as VES events on a DMaaP Message Router topic for consumers that prefer such data in perf3gpp VES format. 


Use Case 1 High Level End-to-End integration Testcases :


#Test CaseStatus
1Ensure that the 'FileReady' VES event is sent from the simulated xNF via the VES collector.

DONE

2Ensure that the unauthenticated.VES_NOTIFICATION_OUTPUT topic is present once it received "File Ready" VES notification from VES Collector.

DONE

3Ensure that the Data File Collector starts to download the xml PM file(s) from the simulated xNF once it receives the 'FileReady' VES event via the VES collector.

DONE

4Ensure that the PM xml file(s) are published to the Data Router.

DONE

5Ensure that a simulated File Consumer is able to subscribe and consume the PM file(s) from the Data Router.

DONE

6Verify the Data File Collector Metadata file is valid

DONE

Use Case 2 High Level End-to-End integration Testcases :


#Test CaseStatus
1Ensure that the 'FileReady' VES event is sent from the simulated xNF via the VES collector.

DONE

2Ensure that the unauthenticated.VES_NOTIFICATION_OUTPUT topic is present once it received "File Ready" VES notification from VES Collector.

DONE

3Ensure that the Data File Collector starts to download the xml PM file(s) from the simulated xNF once it receives the 'FileReady' VES event via the VES collector.

DONE

4Ensure that the PM xml file(s) are published to the Data Router.

DONE

5Verify the Data File Collector Metadata file is valid

DONE

6Verify 3GPP PM Mapper subscribes to feed on the Data Router and maps the PM xml file onto the Message Router as a VES Message(s)

NOT STARTED

7Verify that "simulated PM VES Consumer" receive VES events from Message Router topic.

NOT STARTED

E2E Sunny Day Scenario Sequence Diagram:


JIRAs:

INT-832 - Getting issue details... STATUS

DCAEGEN2-564 - Getting issue details... STATUS

DCAEGEN2-566 - Getting issue details... STATUS

DCAEGEN2-567 - Getting issue details... STATUS

DMAAP-28 - Getting issue details... STATUS

VNFRQTS-513 - Getting issue details... STATUS

INT-649 - Getting issue details... STATUS

VNFRQTS-263 - Getting issue details... STATUS

VNFRQTS-264 - Getting issue details... STATUS   

Deployment:

Test environment requirements for above test cases:

  • xNF simulator for test cases:  FTPes capable server.
  • with VES 7.0.1 support for 'fileReady' event.
    • E.g. xNF able to produce data files and send VES fileReady events,
    • E.g. xNF emulator able to produce 'fileReady' notification events including updated events, or a series or predefined VES events at periodic intervals.
  • sample data files for collection. E.g. 3gpp PM file(s)
  • DMaaP R3, at minimum need DR running and configured for Bulk PM support
  • DCAE R3, MR with support for VES 7.1 spec
  • DCAE R3, Data File Collector installed and configured

This environment can be set up by following the steps below.

  1. Clone the integration/csit repo (git clone ssh://gerrit.onap.org:29418/integration/csit ).
  2. Run: .run-csit.sh plans/usecases/5G-bulkpm

Use Case preconditions:

    • xNF simulator.


Detailed Description End-to-End Feature Integration Testcases :

Test Case ID

Bulk_PM_E2E_01

Test Case NameSend FileReadyEvent to VES Collector
DescriptionEnsure that the 'FileReady' VES event is sent from the simulated xNF to the VES collector.
ReleaseCasablanca
Pre-conditionsFrom the above section "Deployment" a test environment with all the required components - xNF (simulated with sftp or sftpe ), VES Collector are all started.
Testing Steps
StepsExpected Result
  1. Send FileExist VES event to VES collector to simulate what the xNF would initiate.

    Example File Ready VES Notification:

    curl -i -X POST    -H "Content-Type:application/json"    -d '{
        "event": {
            "commonEventHeader": {
                "version": "4.0.1",
                "vesEventListenerVersion": "7.0.1",
                "domain": "notification",
                "eventName": "Noti_RnNode-Ericsson_FileReady",
                "eventId": "FileReady_1797490e-10ae-4d48-9ea7-3d7d790b25e1",
                "lastEpochMicrosec": 8745745764578,
                "priority": "Normal",
                "reportingEntityName": "otenb5309",
                "sequence": 0,
                "sourceName": "oteNB5309",
                "startEpochMicrosec": 8745745764578,
                "timeZoneOffset": "UTC+05.30"
            },
            "notificationFields": {
                "changeIdentifier": "PM_MEAS_FILES",
                "changeType": "FileReady",
                "notificationFieldsVersion": "2.0",
                "arrayOfNamedHashMap": [
                  { "name": "pm.xml.gz",
                    "hashMap":{
                                  "location": "sftp://admin:admin@172.18.0.2:22/pm.xml.gz",
                                  "compression": "gzip",
                                  "fileFormatType": "org.3GPP.32.435#measCollec",
                                  "fileFormatVersion": "V10"
                                  }
                  }
                ]  
            }
        }
      }' 'http://172.17.0.2:8080/eventListener/v7'

The VES Collector accepted the "File Ready" Notification send by xNF.

We should get 202 response from the VES Collector. e.g.

HTTP/1.1 202

Content-Type: application/json

Content-Length: 8

Date: Sat, 22 Sep 2018 21:16:07 GMT



Conclusion (Pass /Fail)PASS
Testing Lab

https://jenkins.onap.org/view/CSIT/ Ubuntu Docker Machine



Test Case IDBulk_PM_E2E_02
Test Case Name

DmaaP topic for unauthenticated.VES_NOTIFICATION_OUTPUT

DescriptionEnsure that the unauthenticated.VES_NOTIFICATION_OUTPUT topic is present on the DMaaP Message Router once it receives "File Ready" VES notification from VES Collector.
ReleaseCasablanca
Pre-conditions

1 .The DmaaP Message Router is up and running.

2. The Previous Test case has passed and its environment is still running

Testing Steps



StepsExpected Result
  1. Check on the DmaaP topic, it should contain "unauthenticated.VES_NOTIFICATION_OUTPUT"
    curl -i http://172.18.0.6:3904/topics

Expect result code 200, e.g.

HTTP/1.1 200 OK
Date: Sun, 23 Sep 2018 10:10:26 GMT
Content-Type: application/json
Accept: */*
breadcrumbId: ID-de84f90a4556-45507-1537643129080-0-21587
User-Agent: curl/7.47.0
X-CSI-Internal-WriteableRequest: true
Content-Length: 87
Server: Jetty(9.3.z-SNAPSHOT)

{"topics": [
    "__consumer_offsets",
    "unauthenticated.VES_NOTIFICATION_OUTPUT"
]}

If you wish to manually check the messages under unauthenticated.VES_NOTIFICATION_OUTPUT topic in DmaaP.

# curl http://172.18.0.6:3904/events/unauthenticated.VES_NOTIFICATION_OUTPUT/OpenDcae-c12/C12

Note: If you manually check the message on the Topic, you will consume it and therefore DFC wont be able to consume it.

["{\"event\":{\"commonEventHeader\":{\"startEpochMicrosec\":8745745764578,\"eventId\":\"FileReady_1797490e-10ae-4d48-9ea7-3d7d790b25e1\",\"timeZoneOffset\":\"UTC+05.30\",\"internalHeaderFields\":{\"collectorTimeStamp\":\"Sat, 09 22 2018 07:09:15 UTC\"},\"priority\":\"Normal\",\"version\":\"4.0.1\",\"reportingEntityName\":\"otenb5309\",\"sequence\":0,\"domain\":\"notification\",\"lastEpochMicrosec\":8745745764578,\"eventName\":\"Noti_RnNode-Ericsson_FileReady\",\"vesEventListenerVersion\":\"7.0.1\",\"sourceName\":\"oteNB5309\"},\"notificationFields\":{\"notificationFieldsVersion\":\"2.0\",\"changeType\":\"FileReady\",\"changeIdentifier\":\"PM_MEAS_FILES\",\"arrayOfNamedHashMap\":[{\"name\":\"pm.xml.gz\",\"hashMap\":{\"location\":\"sftp://admin:admin@172.18.0.2:22/pm.xml.gz\",\"fileFormatType\":\"org.3GPP.32.435#measCollec\",\"fileFormatVersion\":\"V10\",\"compression\":\"gzip\"}}]}}}"]

Conclusion (Pass /Fail)PASS
Testing Labhttps://jenkins.onap.org/view/CSIT/ Ubuntu Docker Machine



Test Case IDBulk_PM_E2E_03
Test Case NameDownload of xml PM file(s) from xNF when 'FileReady' VES event is received.
DescriptionEnsure that the Data File Collector starts to download the xml PM file(s) from the simulated xNF once it receives the 'FileReady' VES event via the VES collector.
ReleaseCasablanca
Pre-conditionsThe Previous Test case has passed and its environment is still running
Testing Steps
StepsExpected Result
  1. File Collector get xNF info ( sftp address, PM file location etc ) from the
     Dmaap topic
     unauthenticated.VES_NOTIFICATION_OUTPUT

    # docker exec -it dfc /bin/sh

    > cat /opt/log/application.log


Data File Collector fetches messages from Dmaap Topic.

2018-09-22 21:16:07.815  INFO 1 --- [elastic-2] o.o.d.c.d.s.DmaapReactiveWebClient       : Request: GET http://172.18.0.6:3904/events/unauthenticated.VES_NOTIFICATION_OUTPUT/OpenDcae-c12/C12
2018-09-22 21:16:07.815  INFO 1 --- [elastic-2] o.o.d.c.d.s.DmaapReactiveWebClient       : Content-Type=application/json
2018-09-22 21:16:07.816  INFO 1 --- [elastic-2] o.o.d.c.d.s.DmaapReactiveWebClient       : HTTP request headers: {Content-Type=[application/json]}
2018-09-22 21:16:08.062  INFO 1 --- [reactor-http-client-epoll-15] o.o.d.c.d.s.DmaapReactiveWebClient       : Response Status 200
2018-09-22 21:16:08.064  INFO 1 --- [reactor-http-client-epoll-15] o.o.d.c.d.s.DmaapConsumerJsonParser      : raw message from message router: ["{"event":{"commonEventHeader":{"startEpochMicrosec":8745745764578,"eventId":"FileReady_1797490e-10ae-4d48-9ea7-3d7d790b25e1","timeZoneOffset":"UTC+05.30","internalHeaderFields":{"collectorTimeStamp":"Sat, 09 22 2018 09:16:07 UTC"},"priority":"Normal","version":"4.0.1","reportingEntityName":"otenb5309","sequence":0,"domain":"notification","lastEpochMicrosec":8745745764578,"eventName":"Noti_RnNode-Ericsson_FileReady","vesEventListenerVersion":"7.0.1","sourceName":"oteNB5309"},"notificationFields":{"notificationFieldsVersion":"2.0","changeType":"FileReady","changeIdentifier":"PM_MEAS_FILES","arrayOfNamedHashMap":[{"name":"pm.xml.gz","hashMap":{"location":"sftp://admin:admin@172.18.0.2:22/pm.xml.gz","fileFormatType":"org.3GPP.32.435#measCollec","fileFormatVersion":"V10","compression":"gzip"}}]}}}"]

2. File Collector start downloading PM files from xNF.

> cat /opt/log/application.log

2018-09-22 21:16:08.811 DEBUG 1 --- [reactor-http-client-epoll-15] o.o.d.c.datafile.ftp.SftpClient          : File pm.xml.gz Download Successfull from xNF

3.Check that DFC successfully publishes to the DR

> cat /opt/log/application.log


The String "Publish to DR successful!" is in the log file


Conclusion (Pass /Fail)PASS
Testing Labhttps://jenkins.onap.org/view/CSIT/ Ubuntu Docker Machine



Test Case IDBulk_PM_E2E_04
Test Case NameFile Collector informs Data Router of xml PM file(s)
DescriptionEnsure that the PM xml file(s) are published to the Data Router.
ReleaseCasablanca
Pre-conditionsThe Previous Test case has passed and its environment is still running
Testing Steps
StepsExpected Result

1 .The File Collector subscribes to the Data Router.

# curl -v -X POST -H "Content-Type:application/vnd.att-dr.feed" -H "X-ATT-DR-ON-BEHALF-OF:dradmin" --data-ascii @$WORKSPACE/test/csit/plans/dcae-bulkpm/bulkpm-suite/assets/createFeed.json --post301 --location-trusted -k https://${DR_PROV_IP}:8443

Where @$WORKSPACE/test/csit/plans/dcae-bulkpm/bulkpm-suite/assets/createFeed.json is e.g.

{
"name": "DefaultFeed",
"version": "m1.0",
"description": "Default feed",
"business_description": "Default Feed",
"suspend": false,
"deleted": false,
"changeowner": true,
"authorization": {
"classification": "unclassified",
"endpoint_addrs": [],
"endpoint_ids": [
{
"password": "dradmin",
"id": "dradmin"
}]
}
}

1.The File Collector is successfully subscribed to the Data Router.

# curl -k https://${DR_PROV_IP}:8443/internal/prov

Should contain https://dmaap-dr-prov/publish/1

2. File Collector informs Data Router of new xml PM files(s)

# curl -v -X POST -H "Content-Type:application/vnd.att-dr.subscription" -H "X-ATT-DR-ON-BEHALF-OF:dradmin" --data-ascii @/tmp/addSubscriber.json --post301 --location-trusted -k https://${DR_PROV_IP}:8443/subscribe/1

Where e.g. /tmp/addSubsriber.json is

{

"delivery":{
"url":"http://192.168.16.9:7070",
"user":"LOGIN",
"password":"PASSWORD",
"use100":true
},
"follow_redirect":false,
"metadataOnly":false,
"suspend":false,
"groupid":0,
"links":{
"self": "https://dmaap-dr-prov/subscribe/1",
"log": "https://dmaap-dr-prov/feedlog/1",
"feed": "https://dmaap-dr-prov/feed/1"
},
"subscriber":"admin"

2. The xml PM file(s) is published on the Data Router.

# curl -k https://${DR_PROV_IP}:8443/internal/prov

Should contain http://X.X.X.X:7070

Where X.X.X.X is the IP-address of the Data Router File Subscriber Simulator.

Conclusion (Pass /Fail)PASS
Testing Labhttps://jenkins.onap.org/view/CSIT/ Ubuntu Docker Machine
Test Case IDBulk_PM_E2E_05
Test Case NameSimulated File Consumer receives the xml PM file(s)
DescriptionEnsure that a simulated File Consumer is able to subscribe and consume the PM file(s) from the Data Router.
ReleaseCasablanca
Pre-conditionsThe Previous Test case has passed and its environment is still running
Testing Steps
StepsExpected Result
  1. A simulated File Consumer subscribes to the Data Router e.g. where the IP-
    address is of the datarouter-prov docker container
    # curl -k https://172.100.0.3:8443/internal/prov
1.The simulated File Consumer is successfully subscribed to the Data Router.

2. A simulated File consumer receives notification of a xml PM file(s)

# docker exec -it subscriber-node bash

> ls -la opt/app/subscriber/delivery/

2.The simulated File Consumer is successfully able to consume the xml PM file(s) from the Data Router.

The pm file is visible on the simulated File Consumer.

pm.xml.gz

Conclusion (Pass /Fail)PASS
Testing Labhttps://jenkins.onap.org/view/CSIT/ Ubuntu Docker Machine
Test Case IDBulk_PM_E2E_06
Test Case Name

Verify the Data File Collector Metadata file is valid

DescriptionVerify that the Metadata for the PM xml file is correct
ReleaseDublin
Pre-conditionsThe Previous Test case has passed and its environment is still running
Testing Steps
StepsExpected Result

1.Copy the Metadata file from the File Consumer docker container

1. File copied to the instance.

2.Verify that the Metadata complies to the schema

2. The Metadata conforms to the schema

Conclusion (Pass /Fail)PASS
Testing Labhttps://jenkins.onap.org/view/CSIT/ Ubuntu Docker Machine
Test Case IDBulk_PM_E2E_07
Test Case NameVerify 3GPP PM Mapper maps the PM xml file onto the Message Router as a Ves Message(s)
DescriptionVerify 3GPP PM Mapper subscribes to feed on the Data Router and maps the PM xml file onto the Message Router as a Ves Message(s)
ReleaseDublin
Pre-conditionsThe Previous Test case has passed and its environment is still running
Testing Steps
StepsExpected Result

1.Verify 3GPP PM Mapper subscribes to feed on the Data Router

1. 3GPP PM Mapper subscribed to feed on the Data Router

2.Verify 3GPP PM Mapper maps the pm XMLfile to a topic on the Message Router as a VES Message(s)

2.The pm XML file is successfully maped to VES Messages on the Message Router Topic

Conclusion (Pass /Fail)-
Testing Labhttps://jenkins.onap.org/view/CSIT/ Ubuntu Docker Machine
Test Case IDBulk_PM_E2E_08
Test Case NameVerify that "simulated PM VES Consumer" receive VES events from Message Router topic.
DescriptionVerify that the "simulated PM VES Consumer" is able to receive the PM VES events from the Message Router topic
ReleaseDublin
Pre-conditionsThe Previous Test case has passed and its environment is still running
Testing Steps
StepsExpected Result

1.Verify that the "simulated PM VES Consumer" is able to subscribe to the Message Router

1. "Simulated PM VES Consumer" is successfully subscribed to feed on the Data Router.

2.Verify that the "simulated PM VES Consumer" receives PM VES Events on the topic on the Message Router that it has subscribed to.

2.PM VES Events are visible on the "simulated PM VES Consumer".

Conclusion (Pass /Fail)-
Testing Labhttps://jenkins.onap.org/view/CSIT/ Ubuntu Docker Machine

Information:

For more information on the DMaaP API's see this link DMaaP API

Next Step(s):

Write Tests cases to verify BulkPM on an ONAP environment.

  • No labels