Projects Name | OOM | Notes |
---|
Health Check | PASSED | - Tested on Local microK8S with OOM
The healthcheck done on the frontend is propagated to the backend, therefore it validates both at the same time. |
CLAMP ↔ DCAE (SB-01) | PASSED | |
CLAMP ↔ Policy (SB-01) | PASSED | - Tested on local Clamp to Windriver Policy (10.12.6.1:30210) Submit / Deploy OK - Stop / Restart OK - PDP group selection and update in the different policies OK - Policy model synchronization, so policies available for loop instance OK - UI generation from policy models OK
- Tested on SB-01, Status of the policies (SENT AND DEPLOYED)
- Submit / Deploy OK - Stop / Restart OK - PDP group selection and update in the different policies OK - Policy model synchronization, so policies available for loop instance OK - UI generation from policy models OK. Bug found and Fixed
CLAMP-801
-
Getting issue details...
STATUS
- Bug found when re-submitting the policies
CLAMP-808
-
Getting issue details...
STATUS
but there is a workaround
|
CLAMP ↔ SDC (SB-01) | PASSED | Tested on SB-01, Distribution done with the new DCAE blueprint TCA, the loop template was available, so it was possible to create a loop instance and submit to policy
Artifacts deployed 2 so it's well ok for CLAMP, the template is well in the CLAMP DB
It prooves the communication with DCAE at this point is also ok, artifact well deployed by SDC on DCAE |
CLAMP → AAF (SB-01) | PASSED | - Tested on Local microK8s with OOM
- Tested on SB-01, authentication successful with P12 certificate
|
CLAMP ↔ CDS (SB-00) | IN PROGRESS | This requires additional testing on SB-01, still need the right CDS parameters |