Overall design
1. Scenario
Let us say, a site has three kinds of compute nodes with respect to SRIOV-NIC
1st set contains, say SRIOV-NIC cards of type XYZ (PCIe vendor ID: 1234 Device ID: 5678) and YUI(PCIe vendor ID:2345 Device ID:6789.
2nd set contains say SRIOV-NIC cards of type ABC (PCIe vendor ID: 4321 Device ID: 8765).
3rd set does not contain any SRIOV NIC cards.
1.1 Openstack Config SRIOV
Openstack configuration:
- NIC configuration refer to https://docs.openstack.org/neutron/pike/admin/config-sriov.html
Create flavors.
Flavor1:$ openstack flavor create flavor1 --id auto --ram 512 --disk 40 --vcpus 4
$ openstack flavor set flavor1 --property pci_passthrough:alias=NIC-sriov-1234-5678-physnet1:1
$ openstack flavor set flavor1 --property pci_passthrough:alias=NIC-sriov-2345-6789-physnet2:1
Flavor2:
$ openstack flavor create flavor2 --id auto --ram 512 --disk 40 --vcpus 4$ openstack flavor set flavor2 --property pci_passthrough:alias=NIC-sriov-4321-8765:2
Flavor3
$ openstack flavor create flavor3 --id auto --ram 512 --disk 40 --vcpus 4
1.2 Mutli-cloud discovery
When it reads the flavors information from openstack site, if the pci_passthrough alias start with NIC-sriov, then it assumes that it is SRIOV NIC type.
Next two integers are meant for vendor id and device id.
If it is present after device id, it is assumed to be provider network.
As part of discovery, it populates the A&AI with two PCIe features for Flavor1.
hpa-feature=”pciePassthrough”,
architecture=”{hw_arch}",
version=”v1”,
Hpa-attribute-key | Hpa-attribute-value |
pciVendorId | 1234 |
pciDeviceId | 5678 |
pciCount | 1 |
interfaceType | SRIOV-NIC |
providerNetwork | Physnet1 |
hpa-feature=”pciePassthrough”,
architecture=”{hw_arch}",
version=”v1”,
Hpa-attribute-key | Hpa-attribute-value |
pciVendorId | 2345 |
pciDeviceId | 6789 |
pciCount | 1 |
interfaceType | SRIOV-NIC |
providerNetwork | Physnet2 |
1.3 SO call OOF
SO will get pciVendorId, pciDeviceId and interfaceType from CSAR file, then call to OOF. OOF will response homing information to SO, SO don't interpret it and pass through it to Multi-cloud.
1.4 VF-C call OOF
VF-C will get pciVendorId, pciDeviceId and interfaceType from CSAR file, then call to OOF. OOF will response homing information to VF-C.
1.5 OOF Response
OOF will match the SRIOV information along with the constraint provided by Policy and add extra attributes inside the assignmentInfo data block when returning the response to SO and VF-C.
Sample looks like below.
"assignmentInfo": [ { "key":"locationType", { "key":"vimId", { "key":"oofDirectives", "directives":[ { "vnfc_directives":[ } ] |
For the newly added oofDirectives, we only return the vnfc part. For example:
"vnfc_directives": [ { "vnfc_id":"", "directives":[ { "directive_name": "flavor_directive", "attributes": [ ] }, { "directive_name": "vnic-info2", ] |
It is worth noting that the vnic-type is converted from interfaceType in OOF.
If interfaceType is SRIOV-NIC, then OOF returns 'vnic-type' as 'direct', If interfaceType is not SRIOV-NIC, OOF return 'vnic-type' as 'normal'.
4. ONAP Module Modify
Module Name | Modification | status | owner | comments |
---|---|---|---|---|
SDC | Add SR-IOV NIC attributes. | Completed | Alex Lianhao | |
Policy | Add SR-IOV NIC attributes. | In Progress | ||
VF-C | Add create port process. | In Progress | Haibin | |
SO | Add create port process. | In Progress | ||
OOF | Add the process for cloud region HPA capabilities | In Progess | Ruoyu | |
AAI | Nothing, we just add one hpa-attribute-key and hpa-attribute-value | Completed | - | now [A] API can support. |
ESR | Add SR-IOV NIC info to cloud extra info. | In Progress | Haibin | |
Multi-cloud | Register SR-IOV info to AAI. | In Progress | Haibin | |
VIM | Config SR-IOV NIC and create network with SR-IOV NIC. | In Progress | Haibin |
[A] PUT /cloud-infrastructure/cloud-regions/cloud-region/{cloud-owner}/{cloud-region-id}/hpa-capabilities/hpa-capability/{hpa-capability-id}
4.1 VF-C Modification
- When it create network, VF-C will get provider network including interface type, physical_network and vnic type from OOF pass it Multi-cloud.
- When we create port , we need pass vnic type to multi-cloud. so we don't modify it.
4.2 Multi-cloud Modification
https://developer.openstack.org/api-ref/network/v2/
- Multi-cloud need to get provider network information and modify all provider network information for the request of submitting to VIM.
- Multi-cloud don't modify VF-C request, just pass to VIMs, so we don't modify it.
4.3 SO Modification
Please Marcus Williams helps to update it.
4.4 OOF Modification
As we known OOF just check /cloud-infrastructure/cloud-regions/cloud-region/{cloud-owner}/{cloud-region-id}/flavors/flavor/{flavor-id}/hpa-capabilities
Now, we need OOF also check and match /cloud-infrastructure/cloud-regions/cloud-region/{cloud-owner}/{cloud-region-id}/hpa-capabilities/hpa-capability/{hpa-capability-id}
Seond, we need to add some attributes in the response returning to SO and VF-C like below.
|
SR-IOV NIC related Capability in Data model
This is refer to Supported HPA Capability Requirements(DRAFT)#LogicalNodei/ORequirements
Logical Node i/O Requirements
Capability Name | Capability Value | Descriptiopn |
---|---|---|
pciVendorId | PCI-SIG vendor ID for the device | |
pciDeviceId | PCI-SIG device ID for the device | |
pciNumDevices | Number of PCI devices required. | |
pciAddress | Geographic location of the PCI device via the standard PCI-SIG addressing model of Domain:Bus:device:function | |
pciDeviceLocalToNumaNode | required notRequired | Determines if I/O device affinity is required. |
Network Interface Requirements
Capability Name | Capability Value | Description |
---|---|---|
nicFeature | LSO, LRO, RSS, RDMA | Long list of NIC related items such as LSO, LRO, RSS, RDMA, etc. |
dataProcessingAccelerationLibray | Dpdk_Version | Name and version of the data processing acceleration library required. Orchestration can match any NIC that is known to be compatible with the specified library. |
interfaceType | Virtio, PCI-Passthrough, SR-IOV, E1000, RTL8139, PCNET | Network interface type |
vendorSpecificNicFeature | TBA | List of vendor specific NIC related items. |
Reference
https://docs.openstack.org/neutron/pike/admin/config-sriov.html
https://builders.intel.com/docs/networkbuilders/EPA_Enablement_Guide_V2.pdf of "2.3 Support for I/O Passthrough via SR-IOV"
Supported HPA Capability Requirements(DRAFT)#LogicalNodei/ORequirements