R2+ AttributesQualifierCardinalityContentDescriptionProducerConsumer
uuidM1String(Identifier)Identifier of Fowarding ConstructSDCSDC/UUI/SDNC
nameO1StringHuman readable name for FCSDCSDC/UUI/SDNC
versionM1StringIdentify the version of FCSDCSDC/UUI/SDNC
descriptionO1StringAdditional infomation for FC descriptionSDCSDC/UUI/SDNC
fcPortDIdM2..NStringReferences the end ports of FC. Each end point is described by FC Port.SDCSDC/UUI/SDNC
fcRouteDIdM0..NStringReferences the fc route which describes the routing relationships within FC.SDCSDC/UUI/SDNC
supportedLinkM0..NStringAn FC that spans between LTPs that terminate the LayerProtocol usually supports one or more links in the client layer. SDCSDC/UUI/SDNC
configurationDIdM0..NStringReferences the specify configurationSDCSDC/UUI/SDNC

FC Port

R2+ AttributesQualifierCardinalityContentDescriptionProducerConsumer
uuidM1String(Identifier)Identifier of Fowarding Construct PointSDCSDC/UUI/SDNC
nameO1StringHuman readable name for FC PortSDCSDC/UUI/SDNC
versionM1StringIdentify the version of FC PortSDCSDC/UUI/SDNC
descriptionO1StringAdditional infomation for FC Port descriptionSDCSDC/UUI/SDNC
addressO0..NStringOne or more descriptions of the location. Such as Ip address or mac address or geo address. SDCSDC/UUI/SDNC
fcPortDirectionO1String

The orientation of the defined flow at the FcPort.

SDCSDC/UUI/SDNC
ltpDIdM0..2StringReferences the ltp. The FcPort may be associated with more than one LTP when the FcPort is bidirectional and the LTPs are unidirectional.SDCSDC/UUI/SDNC
configurationDIdM0..NStringReferences the specify configuration.SDCSDC/UUI/SDNC

Forwarding Domain (FD)

R2+ AttributesQualifierCardinalityContentDescriptionProducerConsumer
uuidM1String(Identifier)Identifier of FDSDCSDC/UUI/SDNC
nameO1StringHuman readable name for FDSDCSDC/UUI/SDNC
versionM1StringIdentify the version of FDSDCSDC/UUI/SDNC
descriptionO1StringAdditional infomation for FD descriptionSDCSDC/UUI/SDNC
addressO0..NStringOne or more descriptions of the location.SDCSDC/UUI/SDNC
lowerLevelFdM0..NStringFD can be exposed as multiple lower level FDs.SDCSDC/UUI/SDNC
ltpDIdM0..NStringAn instance of FD is associated with zero or more LTP objects. The LTPs that bound the FD provide capacity for forwarding. SDCSDC/UUI/SDNC
configurationDIdM0..NStringReferences the specify configurationSDCSDC/UUI/SDNC

FC Route

R2+ AttributesQualifierCardinalityContentDescriptionProducerConsumer
uuidM1String(Identifier)Identifier of FC RouteSDCSDC/UUI/SDNC
nameO1StringHuman readable name for FC RouteSDCSDC/UUI/SDNC
versionM1StringIdentify the version of FC RouteSDCSDC/UUI/SDNC
descriptionO1StringAdditional infomation for FC Route descriptionSDCSDC/UUI/SDNC
fcDIdM0..NStringReferences the lower level FCs which are internal construction of an FC. Lower level FC could belong to different domain.SDCSDC/UUI/SDNC
linkM0..NStringReferences the link which adjacency between two or more FD.SDCSDC/UUI/SDNC
configurationDIdM0..NStringReferences the specify configurationSDCSDC/UUI/SDNC

Logical Termination Point (LTP)

R2+ AttributesQualifierCardinalityContentDescriptionProducerConsumer
uuidM1String(Identifier)Identifier of LTPSDCSDC/UUI/SDNC
nameO1StringHuman readable name for LTPSDCSDC/UUI/SDNC
versionM1StringIdentify the version of LTPSDCSDC/UUI/SDNC
descriptionO1StringAdditional infomation for LTP descriptionSDCSDC/UUI/SDNC
physicalPortReferenceO1StringThe associated physical interfaceSDCSDC/UUI/SDNC
ltpDirectionO1StringThe overall directionality of the LTP.SDCSDC/UUI/SDNC
serverLtpO0..NStringReferences contained LTPs representing servers of this LTP in an inverse multiplexing configuration.SDCSDC/UUI/SDNC
clientLtpO0..NStringReferences contained LTPs representing client traffic of this LTP for normal cases of multiplexing.SDCSDC/UUI/SDNC
configurationDIdM0..NStringReferences the specify configurationSDCSDC/UUI/SDNC

Link

R2+ AttributesQualifierCardinalityContentDescriptionProducerConsumer
uuidM1String(Identifier)Identifier of LinkSDCSDC/UUI/SDNC
nameO1StringHuman readable name for LinkSDCSDC/UUI/SDNC
versionM1StringIdentify the version of LinkSDCSDC/UUI/SDNC
descriptionO1StringAdditional infomation for Link descriptionSDCSDC/UUI/SDNC
fcDidM0..1StringReferences FC which support the linkSDCSDC/UUI/SDNC
linkPortDIdM2..NStringThe association of the Link to LTPs is made via LinkPort.SDCSDC/UUI/SDNC


LinkPort

R2+ AttributesQualifierCardinalityContentDescriptionProducerConsumer
uuidM1String(Identifier)Identifier of LinkPortSDCSDC/UUI/SDNC
nameO1StringHuman readable name for LinkPortSDCSDC/UUI/SDNC
versionM1StringIdentify the version of LinkPortSDCSDC/UUI/SDNC
descriptionO1StringAdditional infomation for LinkPort descriptionSDCSDC/UUI/SDNC
roleM1String

Each LinkPort of the Link has a role (e.g., symmetric, hub, spoke, leaf, root) in the context of the Link with respect to the Link capability.

SDCSDC/UUI/SDNC
ltpDIdM0..2StringReferences ltp. The LinkPort may be associated with more than one LTP when the LinkPort is bidirectional and the LTPs are unidirectional.SDCSDC/UUI/SDNC

Configuration Base

R2+ AttributesQualifierCardinalityContentDescriptionProducerConsumer
uuidM1String(Identifier)Identifier of configurationSDCSDC/UUI/SDNC
nameO1StringHuman readable name for configurationSDCSDC/UUI/SDNC
versionM1StringIdentify the version of configurationSDCSDC/UUI/SDNC
descriptionO1StringAdditional infomation for configuration descriptionSDCSDC/UUI/SDNC
parasM0..NStringSpecify parameters of the configurationSDCSDC/UUI/SDNC
deployOrderO1integerDeploy order of the configuration, smaller number means deploy firstSDCSDC/UUI/SDNC
subConfigurationDIdM0..NStringReferences the sub configurationSDCSDC/UUI/SDNC

Class Explain: