Skip to end of metadata
Go to start of metadata

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 3 Current »

CPE PNF Re-registration

Test Case IDD1
Test Case Name

CPE PNF Re-registration

DescriptionCPE PNF changes location and re-attaches the network in a different OLT. ONAP detects re-location and re-registers the CPE PNF.
ReleaseFrankfurt
Preconditions

- BBS E2E service instance and CPE PNF resource object have been created in AAI by SO
- BBS E2E service instance orchestration-status is "active"
- Access SDN M&C IP is configured in SDNC DG in ONAP
-- GENERIC-RESOURCE-API: bbs-access-connectivity-network-topology-operation-create-huawei.json
-- GENERIC-RESOURCE-API: bbs-access-connectivity-network-topology-operation-delete-huawei.json
- There is connectivity between Access SDN M&C and RESTCONF collector

Testing Steps
  1. Unplug CPE PNF
  2. Plug CPE PNF in different location (at least different OLT port)
Expected Results
  1. Access SDN M&C notifies RESTCONF collector with a PNF registration event
  2. VES mapper maps RESTCONF event to VES message and publish the message in DMaaP's unauthenticated.VES_PNFREG_OUTPUT
  3. PRH consumes PNF registration VES event
  4. PRH updates CPE PNF resource object in AAI with new values
  5. PRH detects that CPE PNF belongs to service instance in orchestration-status=active and publishes a PNF_UPDATE event in DMaaP's unauthenticated.PNF_UPDATE topic
  6. BBS uS consumes PNF_UPDATE event
  7. BBS uS compares attachment-point with the one stored in AAI. If different, publishes event in DMaaP's unauthenticated.DCAE_CL_OUTPUT, policyName="Nomadic_ONT"
  8. BBS policy continues with service reconfiguration
Actual Results
unauthenticated.VES_PNFREG_OPUTPUT
[
    "{\"event\":{\"commonEventHeader\":{\"startEpochMicrosec\":1555076831049,\"eventId\":\"registration_1555076831049\",\"internalHeaderFields\":{\"collectorTimeStamp\":\"Fri, 04 12 2019 04:04:27 UTC\"},\"eventType\":\"pnfRegistration\",\"priority\":\"Normal\",\"version\":\"4.0.1\",\"reportingEntityName\":\"VESMapper\",\"sequence\":0,\"domain\":\"pnfRegistration\",\"lastEpochMicrosec\":1555076831049,\"eventName\":\"pnfRegistration\",\"vesEventListenerVersion\":\"7.0.1\",\"sourceName\":\"Huawei-HWTCC01B7503\"},\"pnfRegistrationFields\":{\"unitType\":\"\",\"serialNumber\":\"HWTCC01B7503\",\"additionalFields\":{\"remote-id\":\"AC9.0234.0338\",\"attachment-point\":\"167772165-5-2\",\"cvlan\":\"11\",\"svlan\":\"101\"},\"pnfRegistrationFieldsVersion\":\"2.0\",\"manufactureDate\":\"\",\"modelNumber\":\"\",\"lastServiceDate\":\"\",\"unitFamily\":\"\",\"vendorName\":\"Huawei\",\"oamV4IpAddress\":\"\",\"oamV6IpAddress\":\"\",\"softwareVersion\":\"v2\"}}}"
]
unauthenticated.PNF_UPDATE
[
    "{\"additionalFields\":{\"remote-id\":\"AC9.0234.0338\",\"attachment-point\":\"167772165-5-2\",\"cvlan\":\"11\",\"svlan\":\"101\"},\"correlationId\":\"Huawei-HWTCC01B7503\"}"
]
BBSep uS log
2019-04-12 16:13:23.194 TRACE 1 --- [ctor-http-nio-8] .u.ReRegistrationDmaapConsumerJsonParser : Event from DMaaP to be parsed:
{"additionalFields":{"remote-id":"AC9.0234.0338","attachment-point":"167772165-5-2","cvlan":"11","svlan":"101"},"correlationId":"Huawei-HWTCC01B7503"}
2019-04-12 16:13:23.195 DEBUG 1 --- [ctor-http-nio-8] o.o.b.e.p.p.ReRegistrationPipeline       : Processing Step: Retrieve PNF. Url: (/aai/v14/network/pnfs/pnf/Huawei-HWTCC01B7503?depth=all)
2019-04-12 16:13:23.195  INFO 1 --- [ctor-http-nio-8] o.o.b.e.p.tasks.AaiClientTaskImpl        : Executing task (PNF Retrieval) for retrieving PNF object
2019-04-12 16:13:23.195 DEBUG 1 --- [ctor-http-nio-8] o.o.b.e.p.utilities.AaiReactiveClient    : Will issue Reactive GET request to URL (/aai/v14/network/pnfs/pnf/Huawei-HWTCC01B7503?depth=all) for object (org.onap.bbs.event.processor.model.PnfAaiObject)
2019-04-12 16:13:23.197 DEBUG 1 --- [ctor-http-nio-8] o.o.b.e.p.utilities.AaiReactiveClient    : Request: GET https://aai.onap:8443/aai/v14/network/pnfs/pnf/Huawei-HWTCC01B7503?depth=all
2019-04-12 16:13:23.197 DEBUG 1 --- [ctor-http-nio-8] o.o.b.e.p.utilities.AaiReactiveClient    : X-FromAppId=bbs
2019-04-12 16:13:23.198 DEBUG 1 --- [ctor-http-nio-8] o.o.b.e.p.utilities.AaiReactiveClient    : Accept=application/json
2019-04-12 16:13:23.198 DEBUG 1 --- [ctor-http-nio-8] o.o.b.e.p.utilities.AaiReactiveClient    : Authorization=Basic QUFJOkFBSQ==
2019-04-12 16:13:23.198 DEBUG 1 --- [ctor-http-nio-8] o.o.b.e.p.utilities.AaiReactiveClient    : Content-Type=application/json
2019-04-12 16:13:23.198 DEBUG 1 --- [ctor-http-nio-8] o.o.b.e.p.utilities.AaiReactiveClient    : Real-Time=true
2019-04-12 16:13:23.198 DEBUG 1 --- [ctor-http-nio-8] o.o.b.e.p.utilities.AaiReactiveClient    : X-TransactionId=9999
2019-04-12 16:13:23.309 DEBUG 1 --- [ctor-http-nio-8] o.o.b.e.p.utilities.AaiReactiveClient    : Response status 200 OK
2019-04-12 16:13:23.311 DEBUG 1 --- [ctor-http-nio-8] o.o.b.e.p.utilities.AaiReactiveClient    : Response body
{"pnf-name":"Huawei-HWTCC01B7503","pnf-id":"4fca7530-062e-4f8a-9404-496832555c29","equip-type":"","equip-vendor":"Huawei","equip-model":"","sw-version":"v2","in-maint":false,"serial-number":"HWTCC01B7503","resource-version":"1555083285880","nf-role":"","relationship-list":{"relationship":[{"related-to":"service-instance","relationship-label":"org.onap.relationships.inventory.ComposedOf","related-link":"/aai/v14/business/customers/customer/BBSCustomer/service-subscriptions/service-subscription/BBS_E2E_Service/service-instances/service-instance/03b92492-c5c0-487a-b414-d5427ab6f041","relationship-data":[{"relationship-key":"customer.global-customer-id","relationship-value":"BBSCustomer"},{"relationship-key":"service-subscription.service-type","relationship-value":"BBS_E2E_Service"},{"relationship-key":"service-instance.service-instance-id","relationship-value":"03b92492-c5c0-487a-b414-d5427ab6f041"}],"related-to-property":[{"property-key":"service-instance.service-instance-name","property-value":"BBS_E2E_Service"}]}]}}
2019-04-12 16:13:23.312  WARN 1 --- [ctor-http-nio-8] o.o.b.e.p.p.ReRegistrationPipeline       : PNF Huawei-HWTCC01B7503 does not have any logical-links bridged. Stop further processing
Conclusion (Pass/Fail)


Testing LabSwisscom Lab
Testing Date
Tester Name


HSIA Service Reconfiguration

Test Case IDD2
Test Case NameHSIA Service Reconfiguration


Description
ReleaseFrankfurt
Preconditions


Testing Steps


Expected Results


Actual Results


Conclusion (Pass/Fail)
Testing LabSwisscom Lab
Testing Date
Tester Name

CPE Authentication (after relocation)

Test Case IDD3
Test Case NameCPE Authentication (after relocation)


Description
ReleaseFrankfurt
Preconditions


Testing Steps


Expected Results


Actual Results


Conclusion (Pass/Fail)


Testing LabSwisscom Lab
Testing Date
Tester Name

HSIA Service Activation and Service Status Change Notification (after relocation)

Test Case IDD4
Test Case Name

HSIA Service Activation and Service Status Change Notification (after relocation)

Description
ReleaseFrankfurt
Preconditions


Testing Steps


Expected Results


Actual Results


Conclusion (Pass/Fail)


Testing LabSwisscom Lab
Testing Date
Tester Name

CPE  power cycle vs CPE re-registration

Test Case IDD5
Test Case Name

CPE power cycle vs CPE re-registration

DescriptionThe customer powers off the CPE and, after some time, powers it on. The CPE registration message (if any) coming from the Access SDN M&C must not be treated as a PNF re-registration in ONAP
ReleaseFrankfurt
Preconditions


Testing Steps


Expected Results


Actual Results


Conclusion (Pass/Fail)


Testing LabSwisscom Lab
Testing Date
Tester Name
  • No labels