---TEST STATUS for Dublin Release ----The Bulk PM feature consists of two main parts
Use Case 1:
Event-driven bulk transfer of monitoring data from an xNF to ONAP/DCAE. A micro-service will listen for 'FileReady' VES events sent from an xNF via the VES collector. Once files become available the collector micro-service will fetch them using protocol such as FTPES
or SFTP. The collected data files are published internally on a DMaaP Data Router (DR) feed.
JIRAs:
Jira Legacy | ||||||||
---|---|---|---|---|---|---|---|---|
|
Jira Legacy | ||||||||
---|---|---|---|---|---|---|---|---|
|
Jira Legacy | ||||||||
---|---|---|---|---|---|---|---|---|
|
A File Consumer node which is a simulated PM file subscriber that subscribe to Data Router feed and receive PM files.
Use Case 2:
Event-driven bulk transfer of monitoring data from an xNF to ONAP/DCAE. A micro-service will listen for 'FileReady' VES events sent from an xNF via the VES collector. Once files become available the collector micro-service will fetch them using protocol such as FTPES or SFTP. The collected data files are published internally on a DMaaP Data Router (DR) feed. The PM mapper receives the files by subscribing to a Data Router feed. The 3GPP PM Mapper micro-service will extract selected (filtered) measurements from a 3GPP XML file and publish them as VES events on a DMaaP Message Router topic for consumers that prefer such data in perf3gpp VES format.
Use Case 1 High Level End-to-End integration Testcases :
# | Test Case | Status | ||||||
---|---|---|---|---|---|---|---|---|
1 | Ensure that the 'FileReady' VES event is sent from the simulated xNF via the VES collector. |
| ||||||
2 | Ensure that the unauthenticated.VES_NOTIFICATION_OUTPUT topic is present once it received "File Ready" VES notification from VES Collector. |
| ||||||
3 | Ensure that the Data File Collector starts to download the xml PM file(s) from the simulated xNF once it receives the 'FileReady' VES event via the VES collector. |
| ||||||
4 | Ensure that the PM xml file(s) are published to the Data Router. |
| ||||||
4a | Ensure that a simulated File Consumer is able to subscribe and consume the PM file(s) from the Data Router. |
| ||||||
5 | Verify the Data File Collector Metadata file is valid |
|
Use Case 2 High Level End-to-End integration Testcases :
# | Test Case | Status | ||||||
---|---|---|---|---|---|---|---|---|
1 | Ensure that the 'FileReady' VES event is sent from the simulated xNF via the VES collector. |
| ||||||
2 | Ensure that the unauthenticated.VES_NOTIFICATION_OUTPUT topic is present once it received "File Ready" VES notification from VES Collector. |
| ||||||
3 | Ensure that the Data File Collector starts to download the xml PM file(s) from the simulated xNF once it receives the 'FileReady' VES event via the VES collector. |
| ||||||
4 | Ensure that the PM xml file(s) are published to the Data Router. |
| ||||||
5 | Verify the Data File Collector Metadata file is valid |
| ||||||
6 | Verify 3GPP PM Mapper subscribes to feed on the Data Router and maps the PM xml file onto the Message Router as a VES Message(s) |
| ||||||
7 | Verify that "simulated PM VES Consumer" receive VES events from Message Router topic. |
|
E2E Sunny Day Scenario Sequence Diagram:
Gliffy | ||||||||
---|---|---|---|---|---|---|---|---|
|
JIRAs:
Jira Legacy | |||||||
---|---|---|---|---|---|---|---|
|
|
|
Jira Legacy | ||||
---|---|---|---|---|
|
|
|
|
Jira Legacy | |||||||
---|---|---|---|---|---|---|---|
|
|
|
Jira Legacy | |||||||
---|---|---|---|---|---|---|---|
|
|
|
Deployment:
Test environment requirements for above test cases:
- xNF simulator for test cases: FTPes capable server.
- with VES 7.0.1 support for 'fileReady' event.
- E.g. xNF able to produce data files and send VES fileReady events,
- E.g. xNF emulator able to produce 'fileReady' notification events including updated events, or a series or predefined VES events at periodic intervals.
- sample data files for collection. E.g. 3gpp PM file(s)
- DMaaP R3, at minimum need DR running and configured for Bulk PM support
- DCAE R3, MR with support for VES 7.1 spec
- DCAE R3, Data File Collector installed and configured
This environment can be set up by following the steps below.
- Clone the integration/csit repo (git clone ssh://gerrit.onap.org:29418/integration/csit ).
- Run: .run-csit.sh plans/usecases/5G-bulkpm
Use Case preconditions:
- xNF simulator.
E2E Sunny Day Scenario Sequence Diagram
Gliffy | ||||||
---|---|---|---|---|---|---|
|
High Level End-to-End feature integration Testcases :
Status | ||||
---|---|---|---|---|
|
Status | ||||
---|---|---|---|---|
|
Status | ||||
---|---|---|---|---|
|
Status | ||||
---|---|---|---|---|
|
Status | ||||
---|---|---|---|---|
|
Status | ||||
---|---|---|---|---|
|
Jira Legacy | ||||||||
---|---|---|---|---|---|---|---|---|
|
Jira Legacy | ||||||||
---|---|---|---|---|---|---|---|---|
|
Jira Legacy | ||||||
---|---|---|---|---|---|---|
|
Jira Legacy | ||||||||
---|---|---|---|---|---|---|---|---|
|
Jira Legacy | ||||||||
---|---|---|---|---|---|---|---|---|
|
Deployment:
Test environment requirements for above test cases:
- xNF simulator for test cases: FTPes capable server.
- with VES 7.0.1 support for 'fileReady' event.
- E.g. xNF able to produce data files and send VES fileReady events,
- E.g. xNF emulator able to produce 'fileReady' notification events including updated events, or a series or predefined VES events at periodic intervals.
- sample data files for collection. E.g. 3gpp PM file(s)
- DMaaP R3, at minimum need DR running and configured for Bulk PM support
- DCAE R3, MR with support for VES 7.1 spec
- DCAE R3, Data File Collector installed and configured
This environment can be set up by following the steps below.
- Clone the integration/csit repo (git clone ssh://gerrit.onap.org:29418/integration/csit ).
- Run: .run-csit.sh plans/usecases/5G-bulkpm
Use Case preconditions:
- xNF simulator.
Detailed Description End-to-End Feature Integration Testcases :
Test Case ID | Bulk_PM_E2E_01 | ||||
---|---|---|---|---|---|
Test Case Name | Send FileReadyEvent to VES Collector | ||||
Description | Ensure that the 'FileReady' VES event is sent from the simulated xNF to the VES collector. | ||||
Release | Casablanca | ||||
Pre-conditions | From the above section "Deployment" a test environment with all the required components - xNF (simulated with sftp or sftpe ), VES Collector are all started. | ||||
Testing Steps |
| ||||
Conclusion (Pass /Fail) | PASS | ||||
Testing Lab | https://jenkins.onap.org/view/CSIT/ Ubuntu Docker Machine |
Test Case ID | Bulk_PM_E2E_02 | ||||||
---|---|---|---|---|---|---|---|
Test Case Name | DmaaP topic for unauthenticated.VES_NOTIFICATION_OUTPUT | ||||||
Description | Ensure that the unauthenticated.VES_NOTIFICATION_OUTPUT topic is present on the DMaaP Message Router once it receives "File Ready" VES notification from VES Collector. | ||||||
Release | Casablanca | ||||||
Pre-conditions | 1 .The DmaaP Message Router is up and running. 2. The Previous Test case has passed and its environment is still running | ||||||
Testing Steps |
| ||||||
Conclusion (Pass /Fail) | PASS | ||||||
Testing Lab | https://jenkins.onap.org/view/CSIT/ Ubuntu Docker Machine |
Test Case ID | Bulk_PM_E2E_03 | ||||||||
---|---|---|---|---|---|---|---|---|---|
Test Case Name | Download of xml PM file(s) from xNF when 'FileReady' VES event is received. | ||||||||
Description | Ensure that the Data File Collector starts to download the xml PM file(s) from the simulated xNF once it receives the 'FileReady' VES event via the VES collector. | ||||||||
Release | Casablanca | ||||||||
Pre-conditions | The Previous Test case has passed and its environment is still running | ||||||||
Testing Steps |
| ||||||||
Conclusion (Pass /Fail) | PASS | Testing Lab | https://jenkins.onap.org/view/CSIT/ Ubuntu Docker Machine
| |||||
Conclusion (Pass /Fail) | PASS | ||||
Testing Lab | https://jenkins.onap.org/view/CSIT/ Ubuntu Docker Machine |
Test Case ID | Bulk_PM_E2E_04 | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Test Case Name | File Collector informs Data Router of xml PM file(s) | ||||||||||||||
Description | Ensure that the PM xml file(s) are published to the Data Router. | ||||||||||||||
Release | Casablanca | ||||||||||||||
Pre-conditions | The Previous Test case has passed and its environment is still running | ||||||||||||||
Testing Steps |
| ||||||||||||||
Conclusion (Pass /Fail) | PASS | ||||||||||||||
Testing Lab | https://jenkins.onap.org/view/CSIT/ Ubuntu Docker Machine |
Test Case ID | Bulk_PM_E2E_04a | ||||||
---|---|---|---|---|---|---|---|
Test Case Name | Simulated File Consumer receives the xml PM file(s) | ||||||
Description | Ensure that a simulated File Consumer is able to subscribe and consume the PM file(s) from the Data Router. | ||||||
Release | Casablanca | ||||||
Pre-conditions | The Previous Test case has passed and its environment is still running | ||||||
Testing Steps |
| ||||||
Conclusion (Pass /Fail) | PASS | ||||||
Testing Lab | https://jenkins.onap.org/view/CSIT/ Ubuntu Docker Machine |
Test Case ID | Bulk_PM_E2E_05 | ||||||
---|---|---|---|---|---|---|---|
Test Case Name | Verify the Data File Collector Metadata file is valid | ||||||
Description | Verify that the Metadata for the PM xml file is correct | ||||||
Release | Dublin | ||||||
Pre-conditions | The Previous Test case has passed and its environment is still running | ||||||
Testing Steps |
| ||||||
Conclusion (Pass /Fail) | PASS | ||||||
Testing Lab | https://jenkins.onap.org/view/CSIT/ Ubuntu Docker Machine |
Test Case ID | Bulk_PM_E2E_ |
---|
06 |
---|
Test Case Name |
Verify PM-Mapper successfully receives uncompressed the PM XML file | |||
Description | Verify 3GPP PM Mapper successfully receives the uncompressed PM xml file from the DataRouter | ||
Release | Dublin | ||
Pre-conditions | The Previous Test case has passed and its environment is still running | ||
Testing Steps |
|
- A simulated File Consumer subscribes to the Data Router e.g. where the IP-
address is of the datarouter-prov docker container
# curl -k https://172.100.0.3:8443/internal/prov
2. A simulated File consumer receives notification of a xml PM file(s)
# docker exec -it subscriber-node bash
> ls -la opt/app/subscriber/delivery/
2.The simulated File Consumer is successfully able to consume the xml PM file(s) from the Data Router.
The pm file is visible on the simulated File Consumer.
pm.xml.gz
Verify the Data File Collector Metadata file is valid
Steps | Expected Result |
---|---|
1.Copy the Metadata file from the File Consumer docker container | 1. File copied to the instance. |
2.Verify that the Metadata complies to the schema | 2. The Metadata conforms to the schema |
Steps | Expected Result |
---|---|
1.Verify 3GPP PM Mapper subscribes to feed on the Data Router | 1. 3GPP PM Mapper subscribed to feed on the Data Router |
2.Verify 3GPP PM Mapper maps the pm XMLfile to a topic on the Message Router as a VES Message(s) | 2.The pm XML file is successfully maped to VES Messages on the Message Router Topic |
Information:
For more information on the DMaaP API's see this link DMaaP API
Next Step(s):
| ||||
Conclusion (Pass /Fail) | PASS | |||
Testing Lab | https://jenkins.onap.org/view/CSIT/ Ubuntu Docker Machine |
Test Case ID | Bulk_PM_E2E_07 | ||||||
---|---|---|---|---|---|---|---|
Test Case Name | Verify PM-Mapper successfully publishes a PMMeasResult VES Messageonto the Message Router Topic "PM_MAPPER" | ||||||
Description | Verify that the PM-Mapper successfully publishes the VES Message on the topic "PM_MAPPER" | ||||||
Release | Dublin | ||||||
Pre-conditions | The Previous Test case has passed and its environment is still running Table | ||||||
Testing Steps |
| ||||||
Conclusion (Pass /Fail) | PASS | ||||||
Testing Lab | https://jenkins.onap.org/view/CSIT/ Ubuntu Docker Machine |
Information:
For more information on the DMaaP API's see this link DMaaP API
Next Step(s):
Write Tests cases to verify BulkPM on an ONAP environment.
Anchor | ||||
---|---|---|---|---|
|
Performance Verification:
- To arrive at the xNF’s that 5G - Bulk PM E2E can handle, two scenarios must be fulfilled and measured.
1.X Number of xNF’s sending a VES FileReady Event every 15 minutes to an ONAP until PM-Mapper has finished processing the last PM file that was sent in that ROP.
2.ONAP looses connection to X Number of xNF’s and ONAP gains re-connection to the xNF after 1 day, this gives a maximum number of new PM files in the VES FileReady event 96*X Number of xNF’s.
1.When adding 70 new xNF’s every 1.5hours to mimic xNFs being added to an ONAP deployment up to 420 xNF (420 new PM files every 15 minutes) , it takes 4 minutes for all the 420 xNF PM Files to be processed in the Bulk PM e2e Flow.
2.For a spike of 420 xNF’s, its took Bulk PM 5 hours to process the backlog i.e all the initial 40,320 (96* 420) PM files and 420 new PM files every 15 minutes.
For more information on how the 420 xNF's was obtained see the slidepack Integration Meeting.pptx