Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

Test Case IDT204
Test Case NameClosed loop deployment
Description

Deploy and activate closed loop control for vCPE

Actual ResultsClosed loop is preset in DCAE with ONAP install, and policy is installed with a preinstalled script (see details in Use Case service design wiki)
Conclusion (Pass/Fail)Pass
Testing LabWindRiver Lab, Integration-SB-03
Testing DateNov. 26, 20172018
Tester NameYang and Brian

...

Test Case IDT302
Test Case NamevCPE Customer Service Instantiation
DescriptionThis test covers the customer service instantiation process, including vBRG emulator and vG and the related configuration.
Actual Results

Customer service successfully instantiated and configured. Need to manually update temp_network_heat_template and network_resource tables to set aic_version_max = 3.0

TODO: screenshotDemo Video

Conclusion (Pass/Fail)Pass
Testing LabWindRiver Lab SB-03
Testing DateNov. 26, 2018
Tester NameYang and Brian

...