OSAM GW:
For the first phase, OSAM GW is going to be stored in OSAM DB. Access Pod can consist of OSAM Gateway as Local OSAM Gateway.
- id(string): identifier for OSAM GW
- Ip IP address(String): IP address of the OSAM GW
...
Access Pod is a PNF that will be fetched from ONAP(AAI). Its relation such as subscribers and devices will be kept in OSAM DB. CorrelationId will play a key role for that purpose. Moreover, PNF location information could be kept in AAI or OSAM DB.(depends on use case).
VENDOR:
Vendor of the device. There is a one to one relationship between the vendor and device. It consists of the following properties:
id (string): Identifier of the Vendor.
match_count(double): match packet count.
- error_count(double): error packet count.
FLOWS:
Consist of the rules which matches the criteria to action. It consists of the following properties:
id (string): Identifier of the Flows.
match_criteria(string): Criteria of the action to apply.
- action(string): The action to apply for the result of the match with match_criteria.
- statistics_id (array): statistics id array of the flows
- time(string): applied time of the flow.
STATICS:
Result statistics of the applied criteria. It consists of the following properties:
id (string): Identifier of the Vendor.
name(string): Name of the Vendor.
ACCESS DEVICE:
Device is an abstract model definition of a physical device. A device can be an OLT or an ONT Device. It consists of the following properties:
id (string): Identifier of the Device.
type(enum): Type indicates the device as an OLT device or an ONT device.
- serial_number(string): Serial number of the Device.
- opStatus(enum): Indicates the current status of the device. It can be active, failed, deactive... de-active.
- adminState(enum): Indicates that device is provisioned or not.
- connectionStatus(enum): Indicates the connection status of the device. It can be unknown, reachable, unreachable...
mac_address (string): Mac address of the device
ipv4_address (string): Ipv4 address of the device
ipv6_address (string): Ipv6 address of the device
- vendor_id (int): (foreign key) vendor id of the device
- access_pod_id(int): (foreign key) access_pod id of the device
PORT:
Port is an abstract model definition of a port. A port can be an OLT or an ONT port. It consists of the following properties:
no (int): Identifier of the port.
type(enum): Type indicates the device as an PON_OLT or an PON_ONT.
- owner_device_id(string): Serial number of the Device.
- opStatus(enum): Indicates the current status of the device. It can be active, failed, deactive...
- adminState(enum): Indicates that device is provisioned or not.
- rx_packets (Double): Received packets count.
- rx_bytes (Double): Received bytes count.
- rx_errors (Double): Received error count.
- tx_packets (Double): Transmitted packets count.
- tx_bytes (Double): Transmitted bytes count.
- tx_errors (Double): Errors count while transmitted.
...
device_id (string): Identifier of the connected device
- port_no (int): Identifier of the connected port.
ADDRESS INFO:
Address info indicates the connection identifier of a device. It consists of the following properties:
...
mac_address (string): Mac address of the device
...
ipv4_address (string): Ipv4 address of the device
...
PMCONFIGS
PmConfigs object represents an array of PmConfig or PmGroupConfig objects.
...
- type : (counter, gauge, state, context) type can be a counter value (to track how many times something has happened), a gauge (for instantaneous measurement types) a state or a context.
- sample_freq : Frequency of the performance measurement
- name : The name of the measurement
- enabled : This value shows if the config is enabled or not.
ACTIVE ALARMS/EVENTS
Alarms and events which are currently occured and active (would be deleted when the alarm state change as passive) with properties:
- id(double): Identifier of the alarm or event.
- alarm_status(enum) :Can be active or deactive
- name (string) : The name of the alarm or event
- time (string): The time which alarm or event occured.
HISTORICAL ALARMS/EVENTS
Keeps all the alarms and events which are occurred with properties:
- id(double): Identifier of the alarm or event.
- alarm_status(enum) :Can be active or de-active.
- name (string): The name of the alarm or event.
- time (string): The time which alarm or event occurred.
NAS CONFIGURATION
It is about remote radius server with properties:
- nas_confiuration_id(double): Identifier of the nas.
- nas_port_id(double): Configuration port of the nas.
- nas_id(double): Radius server id.
AGGREGATION DEVICE
Leaf switch for the connection of the internet with properties:
id (string): Identifier of the Device.
port(string): Connection port.
- ssl_connection(boolean): indacates that ssl_connection is open or not.
- name(string): name of the device.
- state(enum): Indicates that device is active or not.
mac_address (string): Mac address of the device
ipv4_address (string): Ipv4 address of the device
ipv6_address (string): Ipv6 address of the device
- uplink_port(int): uplink port of the device
ACCESS DEVICE TO AGGREGATION DEVICE
Maps the access device to aggregation device with properties:
aggregation_device_id (string): foreign key of aggregation device id.
access_device_id(string): foreign key of access device id.
SUBSCRIBER:
Subscriber is a model object that allows us to provision customer.
- Id(string) -property refers to ONT uniport also it is an identifier for a subscriber. Must be given
- c-tag(int) -it is used by ONT device. Must be given
- s-tag(int)-it is used by ONT OLT device. Must be given
- techProfileId(int) refers to technology profile id. To provision, the subscriber technology profile is required. (Technology profile details will be fetched from Access Pod.)
- upstreamBandwidthProfile(string) refers an upstream(ONT to OLT) traffic bandwidth profile id. (Traffic bandwidth profile details will be fetched from Access Pod.)
- downstreamBandwidthProfile(string) refers a downstream(OLT to ONT) traffic bandwidth profile id. (Traffic bandwidth profile details will be fetched from Access Pod.)
- nasPortId(string) refers a radius server port.
- Subscriber must be matched with OLT. OLT match is done with ConnectionPoint model.
- Connection Point indicates a bridge between OLT-device and Subscriber's ONT. Subscriber model has ConnectionPoint model as property.
CONNECTION POINT:
ConnectionPoint is a model that connects the Subscriber to OLT-Device.
- Id(string) -property refers to a serial number of OLT device
- hardwareIdentifier(string) -refers a mac address of OLT device
- ipAddress(string) -indicates an IP address of OLT device
- nasId(string) -indicates a radius server.