Table of Contents |
---|
Introduction
...
- Notification callback URL is usually provided as input of service creation request.
- Upon activation successful, a notification will be sent back to SDNC from SB domain controller by calling an appropriate DG
- The DG will call an SO API to update the status of the corresponding L1 Access Service.
Async Flow
Async response for MDONS service creation is applicable when we create a MSA based OTN service using Open ROADM NEs. In this case, after service creation is successful in VNC and the Sync Response is received in SO BPMN, SO waits for Async response from VNC/SDNC.
The following URL is exposed by SO for receiving Async notifications:
http://so-bpmn-infra.onap:8081/mso/async/services/updateStatus
The JSON format to be used in POST request is
{
"request-id":"abfcf8f5-1123-4870-b0bc-d4d21b03a9fa",
"response-code":"200",
"response-message":"SUCCESS",
"ack-final-indicator":"Y"
}
Once this response is received, SO performs the following:
- If response-code is 200, the CREATE service request in request DB table is updated as SUCCESS and progress as 100.
- If response-code is not 200, the CREATE service request in request DB table is updated as FAILED.
- If DB update is success, then response code 200 is sent to calling SDNC process.
- If DB update is failure or any exception occurs during update, then response code 500 is sent to calling SDNC process.
- Once the result is updated in request DB, the UUI which monitors the table gets updated as success/failure.
Ideally the Async notification is received in SDNC when the service is activated in VNC and then SDNC passes it to SO. But currently there is an open issue of async notification not reaching SDNC from VNC. So we manually invoke the async URL of SDNC to mimic the Async notification of VNC.
...
For ths, we can use URL for POST:
...
https://167.254.204.118:30267/asyncNotification
The JSON format required for posting in this URL is as below:
{
"input":{
"configuration-response-common":{
"svc-request-id":"d33e2d45-3ee0-486f-af6e-1caf42db0aa7",
"response-code":"200",
"ack-final-indicator":"Y"
},
"service-identifiers":{
"service-name":"async1_MDONS-OTN_Virtuora-MSA",
"common-id":"abfcf8f5-1123-4870-b0bc-d4d21b03a9fa"
}
}
}
SDNC
The DG and notification call back handing in SDNC has already been supported in Frankfurt release. Modification in optical-package as well as in DGs are needed in G Release.
...
Jira Legacy | ||||||||
---|---|---|---|---|---|---|---|---|
|
UpdateStatus Call Back
DESCRIPTION
Update Service Request status in database upon receiving async response from SDNC
REQUEST BODY
application/json
Async response object that needs to be updated.
REQUEST PARAMETERS
NAME | DESCRIPTION | TYPE | DATATYPE |
---|---|---|---|
NAME | DESCRIPTION | TYPE | DATATYPE |
request-id | Request ID of service operation | M | string |
response-code | Response code to indicate success or failure | M | string |
response-message | Response message to indicate status of operation | O | string |
ack-final-indicator | Indicator for final or non-final response | O | string |
RESPONSES
application/json
default
Response codes 200 or 500.
References
Viewtracker |
---|