Projects NameOOMNotes
Health CheckPASSED
  • Tested on Local microK8S with OOM

The healthcheck done on the frontend is propagated to the backend, therefore it validates both at the same time.

CLAMP ↔ DCAE (SB-01)

PASSED
  • Tested on local Clamp to Windriver DCAE (10.12.7.33:30471)

Deploy / Undeploy test DONE with TCA blueprint

  • Tested on SB-01, issue detected CLAMP-804 - Getting issue details... STATUS
  • After the fixes new test with TCA, DCAE deploy operation has been started on DCAE as we can see here:
  • Operation has been reported by DCAE as SUCCESSFUL as we can see here
  • Undeploy has been tried as well and was successfully executed by DCAE
  • Bug found for undeploy status CLAMP-807 - Getting issue details... STATUS but there is a workround
CLAMP ↔ Policy (SB-01)PASSED
  • Tested on local Clamp to Windriver Policy (10.12.6.1:30210) Submit / Deploy OK - Stop / Restart OK  - PDP group selection and update in the different policies OK - Policy model synchronization, so policies available for loop instance OK - UI generation from policy models OK
  • Tested on SB-01, Status of the policies (SENT AND DEPLOYED)
    •                                                         Submit / Deploy OK - Stop / Restart OK  - PDP group selection and update in the different policies OK - Policy model synchronization, so policies available for loop instance OK - UI generation from policy models OK.               Bug found and Fixed CLAMP-801 - Getting issue details... STATUS
    • Bug found when re-submitting the policies CLAMP-808 - Getting issue details... STATUS but there is a workaround
CLAMP ↔ SDC (SB-01)PASSED

Tested on SB-01, Distribution done with the new DCAE blueprint TCA, the loop template was available, so it was possible to create a loop instance and submit to policy

Artifacts deployed 2 so it's well ok for CLAMP, the template is well in the CLAMP DB

It prooves the communication with DCAE at this point is also ok, artifact well deployed by SDC on DCAE

CLAMP  → AAF (SB-01)PASSED
  • Tested on Local microK8s with OOM
  • Tested on SB-01, authentication successful with P12 certificate
CLAMP ↔ CDS (SB-01)PASSED
  • Tested Locally by Vidya
  • Tested on SB-01
  • Sdc distribution of the right artifact