Prerequisite (when running on Windows)

Do a mvn clean install on both directories to pull down the necessary libraries from the POM.

Navigate to csit directory.

Run the following script

sudo bash run-project-csit.sh

Note - The first time this runs it will download all the libraries defined in the CSTI scripts. This may take awhile be patient (smile)

Once the scripts have run, the output should look like the following


As part of this process docker containers are created for cps-and-ncmp, dbpostgresql, ncmp-dmi-plugin, mariadb and sdnc, once the testing is finished these docker containers are stopped and removed.

To prevent these docker containers from being stopped as part of this process for any reason, within the teardown.sh script located in cps/csit/plans/cps comment out the following line.

Potential issues

This issue may also appear when running the scripts from a windows WSL environment

Error response from daemon: invalid IP address in add-host: ""

To resolve this, do the following:

Issue the following command

sudo apt install net-tools
ifconfig

From the eth0 configuration take the inet address

And manually add this address to the LOCAL_IP variable within the setup.sh script located in the following directory cps/csit/plans/cps

Save this configuration.

Run scripts again.

If your tests don't run after doing this, as seen above check for this error.

/tmp/tmp.rgIeMxiRCGrobot_venv/bin/python: Error while finding module specification for 'robot.run' (ModuleNotFoundError: No module named 'robot')

In the file run-csit.sh located within the cps/csit directory

Look for the following line.

python -m robot.run -N ${TESTPLAN} -v WORKSPACE:/tmp ${ROBOT_VARIABLES} ${TESTOPTIONS} ${SUITES}

Change this to

python3 -m robot.run -N ${TESTPLAN} -v WORKSPACE:/tmp ${ROBOT_VARIABLES} ${TESTOPTIONS} ${SUITES}

Run scripts again

If there is further issues downloading libraries due to the system date being out of sync with windows issue the following command and run the scripts again.

sudo hwclock --hctosys