Image
ONAP SDN-R is running in a docker container using ONAP/SDN-C image "onap/sdnc". These images are stored in ONAP Nexus sdnc image.
The image contains Opendaylight in a standard configuration.
Parameter | Content | Description |
---|---|---|
ODL_HOME | /opt/opendaylight | Root location of ODL Karaf directory structure |
JAVA_HOME | Pointing to the java version, used by ODL | |
SDNRWT | true|false | Set true to activate sdnr wt featureset. Set this during container start |
SDNRNORTHBOUND | true|false | Set true to activate sdnr oofpci service. |
WT Service Configuration
Configuration of sdnr wireless transport parameters is in a file. The file contains sections for the different services.
Configuration file location: $ODL_HOME/etc/devicemanager.properties
If SDN-R WT is starting
- and the file exists, the configuration is used.
- if it does not exist it will be created with the default parameters.
Below an example of the content.
[toggleAlarmFilter] taEnabled=true taDelay=3000 [es] esCluster=sdnr esArchiveCheckIntervalSeconds=0 esArchiveLifetimeSeconds=2592000 [dcae] dcaeUrl=off dcaeUserCredentials=admin:admin dcaeHeartbeatPeriodSeconds=120 [aai] aaiUrl=off aaiUserCredentials= aaiHeaders=["X-TransactionId: 9999"] aaiDeleteOnMountpointRemove=false aaiTrustAllCerts=false aaiPropertiesFile= aaiApiVersion=aai/v13 aaiApplicationId=SDNR aaiClientConnectionTimeout=30000 aaiPcks12ClientCertFile= aaiPcks12ClientCertPassphrase= [pm] pmEnabled=true pmCluster=sdnr [devicemonitor] SeverityconnectionLossOAM=Major SeverityconnectionLossMediator=Major SeverityconnectionLossNeOAM=Major
Sections
toggleAlarmFilter
Configure toggle alarm filter.
taEnabled=true taDelay=3000
Parameter | Values | Default | Unit | Description |
---|---|---|---|---|
taEnabled | true, false | false | Enable or disable this service | |
taDelay | number | milliseconds | Integration time to take over the new alarm status |
devicemonitor
Configure alarm severity of related alarms, generated by Device Monitor.
Syntax: Parameter=Value
Example: SeverityconnectionLossOAM=Major
Values | Default | Unit | Description | |
---|---|---|---|---|
SeverityconnectionLossOAM | NonAlarmed, Warning, Minor, Major, Critical | Major | SDN-Controller <> Mediator Mountpoint monitoring. Indicates a not connected mounpoint | |
SeverityconnectionLossMediator | NonAlarmed, Warning, Minor, Major, Critical | Major | SDN-Controller <> NetworkElement Device monitoring. No LTPs provided | |
SeverityconnectionLossNeOAM | NonAlarmed, Warning, Minor, Major, Critical | Major | SDN-Controller <> NetworkElement Device monitoring. SSH Connetion, Core model not answering |