Comment: Updated Level 1 Resiliency to add "within a single site"

...

  • Level 0: no redundancy
  • Level 1: support manual failure detection & rerouting or recovery within a single site; tested to complete in 30 minutes
  • Level 2: support automated failure detection & rerouting 
    • within a single geographic site
    • stateless components: establish baseline measure of failed requests for a component failure within a site 
    • stateful components: establish baseline of data loss for a component failure within a site
  • Level 3: support automated failover detection & rerouting 

    • across multiple sites 

    • stateless components 

      • improve on # of failed requests for component failure within a site 

      • establish baseline for failed requests for site failure 

    • stateful components 

      • improve on data loss metrics for component failure within a site 

      • establish baseline for data loss for site failure

  • These levels may drive the need for a common platform for resiliency & approaches to consistently provide resiliency across ONAP. Such a platform might contain: 
    1. a geo-distributed database that supports both within and cross-site state replication
    2. a failover mechanism that performs failure detection, request rerouting and the actual failover and 
    3. a site/replica selection service that picks among the appropriate replicas during request rerouting.  

...