TIC Location | VNFs | Intended VNF Provider | VNF CSAR |
Edge | vSBC | Huawei | vSBC_Huawei.csar |
vPCSCF | Huawei | vPCRF_Huawei.csar | |
vSPGW | ZTE/Huawei | vSPGW_ZTE.csar | |
Core | vPCRF | Huawei | vPCRF_Huawei.csar |
VI/SCSCF | HuaweiNokia | VI/SCSCF_Nokia.csar | |
vTAS | NokiaHuawei | Confirmed | |
VHSS | Huawei | vHSS_Huawei.csar | |
vMME | ZTE/Huawei | vMME_Huawei.csar |
Note: The above captures the currently committed VNF providers, we are open to adding more VNF providers.
...
TIC Location | NFVI+VIMs | Intended VIM Provider | Notes |
Edge | Titanium Cloud (OpenStack based) | Wind River | Confirmed |
VMware Integrated OpenStack | VMware | Confirmed | |
Core | Titanium Cloud (OpenStack based) | Wind River | Confirmed |
VMware Integrated OpenStack | VMware | Confirmed |
Note: The above captures the currently committed VIM providers, we are open to adding more VIM providers.
...
Network equipment | intended provider | Notes |
---|---|---|
Bare Metal Host | Huawei, ZTE | Confirmed |
WAN/SPTN Router (2) | Huawei, /ZTE | Confirmed |
DC Gateway | Huawei, ZTE | Confirmed |
TOR | Huawei,ZTE | Confirmed |
Wireless Access Point | Raisecom | Confirmed |
VoLTE Terminal Devices | Raisecom | Confirmed |
Note: The above captures the currently committed HW providers, we are open to adding more HW providers.
...
- Design
- 1.0: ONAP user uses SDC to import and design VoLTE E2E model/templates via Portal. The E2E models should include, vIMS + vEPC network services, SDN-WAN connection services, relevant auto-healing policy and alarm correlation rules, etc. All of these should be tied together as a E2E VoLTE model
SDC/CLAMP should distribute all above models to related components in run time when use need to instantiate the E2E VoLTE service. - 1.1 Distribute E2E model to to SO.
- 1.2 Distribute vIMS+vEPC NS to VF-C,
- 1.3 Distribute SDN-WAN connection service to SDN-C
- 1.4 Distribute auto-healing policy to Policy engine
- 1.5 Distribute alarm correlation rules to Holmes engine.
- 1.6 Design and Distribute DCAE configuration from CLAMP
...
After the fault detected and its root correlated, ONAP should do the auto-healing action as specified by a given policy to make the system back to normal.
More details about the VoLTE use case control loop.
Configuration flows (Stretch goal)
...
- OOM
Support to deploy and operate new added components into ONAP, such as VF-C/Holmes - MSB
Support to route requests to components correctly. - Use Case UISupport UI
Support VoLTE case lifecycle management actions, monitor service instances status, display FCAPS metrics data in real time. - ESR
Support to register 3rd Party VIMs, VNFMs, EMSs and SDN controllers to ONAP
Priorities:
1 means the highest priority.
...