...
Epic | User Story | Task | Description | Honolulu Plan? | JIRA | Size (S/M/L/XL) | Priority | ||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Support Onboard ETSI 3.3.1 SOL004 compliant VNF / CNF packages |
| Yes |
| 4 weeks for one designer | High | ||||||||||
Support for onboarding ETSI v3.3.1 SOL004 VNF CSAR Packages with minimum CNF enhancements from 4.1.1 |
source: Artifacts/helm/helm_charts.yaml
| Yes |
| High | |||||||||||
Determine the onboarding path based on manifest metadata |
| High | |||||||||||||
Create a new onboarding path for SOL004 3.3.1 VNF package |
| High | |||||||||||||
Support the SOL001 vnf_profile properties | SDC needs to support the SOL001 vnf_profile (toaca.databypes.nfv.VnfProfile) properties |
| High | ||||||||||||
Support for onboarding ETSI v3.3.1 SOL001 VNF Descriptors |
| Yes |
| High | |||||||||||
Determine the onboarding path based on metadata |
| ||||||||||||||
Create a new onboarding path for SOL001 VNFD 3.3.1 |
| ||||||||||||||
Support for onboarding ETSI v3.3.1 SOL001 VNF Descriptors with minimum CNF enhancements from 4.1.1 | SDC users need to onboard ETSI 3.3.1 with minimum CNF enhancements from 4.1.1
| Yes |
| High | |||||||||||
Support minimum CNF enhancements from 4.1.1 | Support the vnfd_type with CNF attributes from 4.1.1:
| ||||||||||||||
Extend the 3.3.1 VNFD onboarding path for CNF attributes | Extend the 3.3.1 VNFD onboarding logic for CNF attribute handling | ||||||||||||||
=========== | |||||||||||||||
Support for mapping of ETSI v3.3.1 SOL001 VNF Descriptor into SDC AID Data Model | Once SDC onboards an ETSI v3.3.1 SOL001 VNF Descriptor, SDC needs to map the ETSI v3.3.1 SOL001 VNF Descriptor into SDC AID Data Model
VNF Mapping:
VDU Mapping:
VF-Module Mapping (Stretch goal)
SDC supports Interface mapping to SDC AID DM for creating Service and connect VNF to external networking, etc. Capacity and requirement mapping won't be necessary in this release | Yes |
| Medium (VF-Module mapping is a stretch goal) | |||||||||||
Map VNF data type to SDC AID DM VF | Map VNF data type to SDC AID DM VF | ||||||||||||||
Map VDU data type to SDC AID DM VFC | Map VDU data type to SDC AID DM VFC | ||||||||||||||
Deduce VF-Module from VNFD Policies | Deduce VF-Module from VNFD Policies | ||||||||||||||
Map VNF Interfaces to SDC AID DM | Map VNF Interfaces to SDC AID DM | ||||||||||||||
Support for mapping of ETSI v3.3.1 SOL001 VNF Descriptor with minimum CNF enhancements from 4.1.1 into SDC AID Data Model | Once SDC onboards an ETSI v3.3.1 SOL001 VNF Descriptor with CNF enhancements, SDC needs to map the ETSI v3.3.1 SOL001 VNF Descriptor with minimum CNF enhancements from 4.1.1 into SDC AID Data Model
| Yes |
| medium | |||||||||||
Map VNF with CNF properties to SDC AID DM | |||||||||||||||
Map VDU with CNF properties to SDC AID DM | |||||||||||||||
Map virtualCPD to SDC AID DM | |||||||||||||||
Map MCIOP to SDC AID DM | |||||||||||||||
Support for editing ETSI v3.3.1 SOL001 VNF / CNF Descriptor | SDC users should be able to edit onboarded ETSI v3.3.1 SOL001 VNF Descriptors
Note: should we reflect the changes to original vendor packages in ETSI_PACKAGE directory??? need to think about impact... SDC generates a new digital signature for the package and distributes it to ETSI Catalog Manager. | Yes |
| medium | |||||||||||
Enhance SDC UI for editing SOL001 VNF / CNF descriptor properties | Enhance SDC UI for editing SOL001 VNF / CNF descriptor properties | ||||||||||||||
Design ETSI SOL007 compliant Network Service Descriptor packages |
| Yes |
| 1 week for one designer | High | ||||||||||
Support for designing an ETSI SOL001 v3.3.1 compliant Network Service that can be deployed with an ETSI compliant NFVO | SDC users need to design an ETSI SOL001 v3.3.1 compliant Network Service that can be deployed with an ETSI compliant NFVO
| Yes |
| High | |||||||||||
Enhance SDC design for creating v3.3.1 NS | Enhance SDC design for creating v3.3.1 NS | ||||||||||||||
Generate v3.3.1 SOL007 NS package | Generate v3.3.1 SOL007 NS package
| ||||||||||||||
Compose of one or more VNFs and the Virtual Links that connect them | SDC users need to compose one or more VNFs and the Virtual Links that connect them in NS
Note: cover the VNF version validation... SAP descriptor has a version... | Yes |
| High | |||||||||||
Enhance SDC to compose v3.3.1 VNFs and VLs for v3.3.1 NS | Enhance SDC to allow compose v3.3.1 VNFs and VLs for v3.3.1 NS | ||||||||||||||
Validate NSD and VNFD version match | Validate NSD and VNFD version match
| ||||||||||||||
Support for compose VNFs with CNF enhancements | SDC users need to compose VNFs with CNF enhancements
| Yes |
| High | |||||||||||
Enhance SDC to compose v3.3.1 VNFs with CNF enhancements | Enhance SDC to compose v3.3.1 VNFs with CNF enhancements | ||||||||||||||
Support for mapping of ETSI v3.3.1 SOL001 Network Service Descriptor in the SOL007 package into SDC AID Data Model | SDC needs to support for mapping of ETSI SOL001 Network Service Descriptor in the SOL007 package into SDC AID Data Model
| Yes |
| Medium | |||||||||||
Map v3.3.1 NSD to SDC AID DM | Map v3.3.1 NSD to SDC AID DM | ||||||||||||||
Suport Interfaces | Suport NS Interfaces to SDC AID DM | ||||||||||||||
Support design of Service templates, leveraging NSDs | SDC users need to support design of Service templates, leveraging NSDs ONAP service references NSDs... | Yes |
| Medium | |||||||||||
Compose Service Templates referencing NSDs | Compose Service Templates referencing NSDs | ||||||||||||||
Design Nested/Hierarchical ETSI SOL001 v3.3.1 Network Service Descriptor package |
| No |
| N/A | |||||||||||
Compose of zero or more VNFs and one or more nested Network Services and the Virtual Links that connect them | SDC users need to compose zero or more VNFs and one or more nested Network Services and the Virtual Links that connect them | No |
| N/A | |||||||||||
Support for using VNFs with CNF enhancements | Support design of Service templates, leveraging NSDs | No |
| N/A | |||||||||||
Onboard Prototype Package based on ETSI IFA011 v4.1.1 supporting containerized VNF (CNF) packages |
| No |
| N/A | |||||||||||
Support for onboarding Prototype v4.1.1 CSAR Packages | SDC needs to support onboarding prototype v4.1.1 CSAR packages with CNF artifacts and metadata | No |
| ||||||||||||
Support for onboarding Prototype v4.1.1 VNF/CNF Descriptor | SDC needs to support onboarding prototype v4.1.1 VNF/CNF descriptor | No |
| ||||||||||||
Support for mapping of Prototype v4.1.1 VNF/CNF Descriptor into SDC AID Data Model | SDC needs to support mapping of prototype v4.1.1 VNF/CNF Descriptor into SDC AID Data Model | No |
| ||||||||||||
Support for using a Prototype v4.1.1 VNF in an ETSI Network Service | SDC needs to support for a prototype v4.1.1 VNF/CNF in an ETSI network Service | No |
| ||||||||||||
Onboard ETSI 3.3.1 SOL004 compliant PNF packages | Executive Summary - Enable a vendor provided ETSI 3.3.1 SOL004 compliant PNF package including an ETSI SOL001 PNF Descriptor to be onboarded into ONAP for composition into an ONAP Service Business Impact - Enables operators and service providers to use same ETSI compliant PNF packages with ONAP and existing NFVO. Industry compatibility. Business Markets - All operators that are currently using ETSI packages to deploy PNFs Funding/Financial Impacts - Reduction in operations expense from using industry standard PNF packaging. Reduction in capital expense from vendors using a single packaging methodology. Organization Mgmt, Sales Strategies -There is no additional organizational management or sales strategies for this requirement outside of a service providers "normal" ONAP deployment and its attendant organizational resources from a service provider. | No |
| N/A | |||||||||||
SDC supports onboarding of the 3.3.1 SOL004 PNF package includes SOL001 PNFD |
| No |
| N/A | |||||||||||
Support for mapping of ETSI v3.3.1 SOL001 PNF Descriptor into SDC AID Data Model | SDC needs to support 3.3.1 SOL001 PNFD Mapping to SDC AID DM | No |
| N/A | |||||||||||
Onboard ETSI SOL007 compliant Network Service Descriptor packages | Executive Summary - Onboard an ETSI SOL007 v3.3.1 compliant (Link to ETSI SOL007 v3.3.1) Network Service Descriptor package including an ETSI version 3.3.1 SOL001 Network Service Descriptor (NSD) to be onboarded into ONAP for composition into an ONAP Service or deployment using an ETSI compliant NFVO.
Business Markets - All operators and service providers that are developing ETSI compatible Network Services Funding/Financial Impacts - Reduction in operations expense from using industry standard NSD packaging. Organization Mgmt, Sales Strategies -There is no additional organizational management or sales strategies for this requirement outside of a service providers "normal" ONAP deployment and its attendant organizational resources from a service provider. | No |
| N/A | |||||||||||
Support onboarding for Cataloging and Preserving the original SOL007 package | SDC users need to support onboarding for Cataloging and Preserving the original SOL007 package (Link to ETSI SOL001 v3.3.1) | No |
| N/A | |||||||||||
Support for onboarding of the SOL007 v3.3.1 compliant NSD package including SOL001 NSD that includes references to other NSDs for composition into ONAP Service | SDC users need to support for onboarding of the SOL007 v3.3.1 compliant NSD package including SOL001 NSD that includes references to other NSDs for composition into ONAP Service | No |
| N/A | |||||||||||
Support ETSI Package Security and validation | ONAP supports vendor ETSI 3.3.1Package Security and validation
| Yes |
| 4 weeks for one designer | High | ||||||||||
| ONAP SDC supports ETSI 3.3.1 SOL004 VNF/PNF Package security | Yes | |||||||||||||
| ONAP SDC supports ETSI 3.3.1 SOL007 NS Package security | Yes |
| High | |||||||||||
Support of ETSI Package Validation | VNF SDK will support ETSI package validation for VNF and NS | TBD | N/A | ||||||||||||
VNF SDK will support ETSI VNF package pre-onboarding for validation | VNF SDK will support ETSI VNF package pre-onboarding for validation | TBD | N/A | ||||||||||||
VNF SDK will support ETSI NS package pre-onboarding for validation | VNF SDK will support ETSI NS package pre-onboarding for validation | TBD | N/A |
...
- Enhancement (Ericsson contribution) was made to the SDC Dublin to support SOL004 PNF/VNF onboarding with .zip and .csar file extensions.
- SDC VSP and Resource csar files have the ETSI_PACKAGE, which contains the original vendor VNF package.
- The VNFM and external NFVO use the original vendor VNF/NS packages.
- ONAP-ETSI Catalog Manager will be changed for the location of the original vendor package.
- SOL007 NS onboarding will follow the same procedure; i.e., storing the vendor SOL007 NS package into the ETSI_PACKAGE directory.
- SDC VSP and Resource csar files have the ETSI_PACKAGE, which contains the original vendor VNF package.
- In Guilin, the ONBOARDED_PACKAGE directory is changed to the ETSI_PACKAGE directory.
- At onboarding, SDC checks the file extension and performs the following procedures
- If the file is .zip, SDC unzips
- If it has .cert & .cms, it is a package with security and security validation will be performed.
- If it does not include .cert & .cms, it is an existing Heat template onboarding, and SDC follows the Heat template onboarding procedure
- If the file is .zip, SDC unzips
- If the file is .csar, it is a package without security.
- Next, SDC will check the TOSCA.meta file.
- If it contains SOL004v2.x.1 keywords, the package will be handled as SOL004v2.x.1. In the Guilin release, v3.3.1 will be supported.
- Otherwise, it will be handled as existing TOSCA (non-SOL004) package onboarding which will not have the ETSI_PACKAGE artifact.
NS Onboarding Design
...
Gliffy | ||||||
---|---|---|---|---|---|---|
|
- SOL004 VNF/PNF and SOL007 NS Packages are onboarded to SDC.
- SDC creates its Resource CSAR by adding ONAP-specific files and metadata according to SDC procedure.
- For VNF onboarding, SOL001 VNFD is mapped to SDC Data Model.
- For NS onboarding, SOL001 NSD is mapped to SDC Data Model. Note: the SDC NS Data Model would be SOL001 NSD-based.
- For PNF onboarding, SOL001 PNFD is mapped to SDC Data Model.
- The original SOL004 VNF/PNF and SOL007 NS packages will be stored in the ETSI_PACKAGE directory.
- SDC shall have a capability to design SOL007 NSDs and generates SOL007 NS packages
- Since SDC does not have a proper NS Model, it will follow SOL001 NSD.
- SDC embeds the Resource CSAR into its Service CSAR for distribution.
- After SDC validates the onboarded packages, the Service CSAR is distributed.
- SDC sends the package notification to DMaaP for its package notification subscribers.
- ETSI Catalog Manager receives the package notification from SDC.
- ETSI Catalog Manager queries SDC for the SDC CSAR.
- ETSI Catalog Managers examines the SDC CSAR. If the SDC CSAR contains the ETSI_PACKAGE directory, it extracts the SOL004/SOL007 packages from the directory.
- ETSI Catalog Manager stores the SOL004/SOL007 packages to its Catalog Database.
- ETSI Catalog Manager provides APIs for the SOL003/SOL005 Adapters to distribute the packages to SVNFM/NFVO.
- ETSI Catalog Manager queries SDC for the SDC CSAR.
SOL004 and SOL001 v3.3.1 + 4.1.1 (hybrid) Onboarding
Gliffy macroId d34e147d-5457-466e-a4b2-206abd612a83 name SOL004 VNF-CNF structure onboarding - Honolulu pagePin 19
Design NS
NSD Structure
SDC supports NSD design that meets the following requirements.
...
- SDC supports the following NSD Information Elements.
- SDC supports the netestedNsdId(s) for nested NSDs. (not for Guilin)
- SDC UI should be able to manage the NSD attributes.
- SDC supports the virtualLinkDesc(s) to define constituent VLs.
Use Cases for Guilin
...
- SDC should be able to reference the vCPE NSD from the E2E Service model.
- SDC should be able to reference all the constituent VNFs and VL(s).
<example>
- Test with vGW and VGMUX with a VL first.
...
- SDC supports NSVLDs that are defined in the ETSI IFA 014, as part of NS design.
- SDC UI should be able to handle the following VLD attributes.
VNFD Composition
...
The following Data Model link define VNFD and its sub node types.
ETSI SOL001 VNF/CNF Data Model Based on ETSI v3.3.1 SOL001 plus CNF Enhancements
VNFD Information element
The following depicts the VNFD information element.
SapD Composition
SapD fulfills the following information element.
Distribution
ETSI packages will be distributed from SDC to the ETSI Catalog Manager for other ONAP runtime components such as SO (SOL003/SOL005 Adapter) and VF-C.
...
ETSI Catalog Manager will interface with the SDC directly, without a help from ONAP SO.
Package Distribution Components Interactions
...
- Vendor SOL004/SOL007 VNF Package with certificate and signature is onboarded into SDC
- ZIP-format VNF package includes CSAR, Signature and Certificate
- SDC validates VNF package based on the certificate and signature
- SDC generates SDC internal model plus the vendor SOL004/SOL007 package CSAR and ZIP (with certificate and signature) – the supported format is TBD based on the security requirement
Package Security
...
Current Mapping Support (as of Frankfurt)
Note: AAI impacts are under discussion.
...
NSD Mapping to SDC AID DM
Initial Input
NSD Mapping to SDC AID DM
...
<tosca.datatypes.nfv.NsProfile>
SDC TOSCA Repository
SDC nfv-types
SDC nfv-types/NSD
...
SOL001 VNF (tosca.nodes.nfv.VNF)
| SDC AID DM VNF (org.openecomp.resource.abstract.nodes.VF)
| org.openecomp.resource.vf.vcpeInfrastructureGwDemoApp (derived from org.openecomp.resource.abstract.nodes.VF) | ||||||||
---|---|---|---|---|---|---|---|---|---|---|
name | required | type | name | required | type | name | required | type | ||
descriptor_id | yes | string | nf_function | string | nf_function | string | ||||
descriptor_version | yes | string | nf_role | string | nf_role | string | ||||
provider | yes | string | nf_type | string | nf_type | string | ||||
product_name | yes | string | nf_naming_code | string | nf_name_code | string | ||||
software_version | yes | string | nf_naming | org.openecomp.datatyhpes.Naming | nf_naming | org.openecomp.datatyhpes.Naming | ||||
product_info_name | no | string | availability_zone_max_count | integer | availablity_zone_max_count | integer | ||||
vnfm_info | yes | list of string | min_instances | integer | min_instances | integer | ||||
localization_languages | no | list of string | max_instances | integer | max_instances | integer | ||||
default_localization_language | no | string | multi_stage_design | boolean | multi_stage_design | boolean | ||||
configurable_properties | no | tosca.datatypes.nfv.VnfconfigurableProperties | sdnc_model_name | string | vf_module_id | no | ||||
modifiable_attributes | no | tosca.datatypes.nfv.VnfInfoModifiableAttributes | sdnc_artifact_name | string | vcpe_image_name | no | ||||
lcm_operations_configuraion | no | tosca.datatypes.nfv.VnfLcmOperationsConfiguration | skip_post_instantiation_configuration | boolean (default true)
| public_net_id | no | ||||
monitoring_parameters | no | list of tosca.dataypes.nfv.VnfMonitoringParameter | controller_actor | string (default: SO-REF-DATA)
| vgw_name_0 | no | ||||
flavour_id | yes | string | nexus_artifact_repo | no | ||||||
flavour_description | yes | string | mux_ip_addr | no | ||||||
vnf_profile | no | tosca.datatyhpes.nfv.VnfProfile | vnf_id | no | ||||||
mciop_profile | no | list of tosca.datatypes.nfv.MciopProfile | cpe_public_net_cidr | no | ||||||
vg_vgmux_tunnel_vni | no | |||||||||
nf_naming | no | |||||||||
multi_stage_design | no | |||||||||
<tosca.datatypes.nfv.VnfProfile> | nf_naming_code | no | ||||||||
instantiation_level | no | string | vgw_private_ip_0 | no | ||||||
min_number_of_instances | yes | integer | vgw_private_ip_1 | no | ||||||
max_number_of_instances | yes | integer | vgw_private_ip_2 | no | ||||||
pub_key | no | |||||||||
install_script_version | no | |||||||||
onap_private_net_cidr | no | |||||||||
cpe_public_net_id | no | |||||||||
mux_gw_private_net_id | no | |||||||||
dcae_collector_ip | no | |||||||||
dcae_collector_port | no | |||||||||
onap_private_net_id | no | |||||||||
cloud_env | no |
...
- Make the org.openecomp.resource.abstract.nodes.ETSI.VNF a superset of both tosca.nodes.nfv.VNF and org.openecomp.resource.abstract.node.VF
- During VNF onboarding, SDC copies SOL001 VNF attribute contents to the corresponding attributes in the org.openecomp.resource.abstract.nodes.ETSI.VNF
- In Guilin, SO NFVO, VFC and SVNFM get those SOL001 VNF attributes from the descriptor, not from AAI. So, AAI schema changes are not expected in Guilin.
- SOL001 VNF attributes in SDC AID DM VNF will be visible to SDC UI, so SDC UI can change the attributes.
- But the onboarded vendor ETSI package will note be changed by the SDC UI users in Guilin.
- Since SO NFVO, VFC and SVNFM use only the original ETSI package, those changes will not be used in Guilin;
- For the Honolulu release, it is under consideration
- to sync up between those modified SOL001 VNF attributes and the vendor ETSI Package attributes
- to reflect those modified SOL001 VNF attributes in the orchestration
- ONAP specific attributes that are inherited from the org.openecomp.resource.abstract.nodes.VF will be filled up by SDC (design time)
- Those attribute contents will not be mapped back into the SOL001 VNF (reverse mapping). For that case, only the SOL001 VNF corresponding attributes will be copied
SOL001 VNF (tosca.nodes.nfv.VNF) | Mapping | New SDC AID DM VNF (org.openecomp.resource.abstract.nodes.ETSI.VNF) derived from org.openecomp.resource.abstract.nodes.VF | ||||
---|---|---|---|---|---|---|
name | required | type | name | required | type | |
<SOL001 tosca.nodes.nfv.VNF attributes > | <SOL001 tosca.nodes.nfv.VNF attributes > | |||||
descriptor_id | yes | string | <--> | descriptor_id | yes | string |
descriptor_version | yes | string | <--> | descriptor_version | yes | string |
provider | yes | string | <--> | provider | yes | string |
product_name | yes | string | <--> | product_name | yes | string |
software_version | yes | string | <--> | software_version | yes | string |
product_info_name | no | string | <--> | product_info_name | no | string |
vnfm_info | yes | list of string | <--> | vnfm_info | yes | list of string |
localization_languages | no | list of string | <--> | localization_languages | no | list of string |
default_localization_language | no | string | <--> | default_localization_language | no | string |
configurable_properties | no | tosca.datatypes.nfv.VnfconfigurableProperties | <--> | configurable_properties | no | tosca.datatypes.nfv.VnfconfigurableProperties |
modifiable_attributes | no | tosca.datatypes.nfv.VnfInfoModifiableAttributes | <--> | modifiable_attributes | no | tosca.datatypes.nfv.VnfInfoModifiableAttributes |
lcm_operations_configuration | no | tosca.datatypes.nfv.VnfLcmOperationsConfiguration | <--> | lcm_operations_configuration | no | tosca.datatypes.nfv.VnfLcmOperationsConfiguration |
monitoring_parameters | no | list of tosca.datatypes.nfv.VnfMonitoringParameter | <--> | monitoring_parameters | no | list of tosca.datatypes.nfv.VnfMonitoringParameter |
flavour_id | yes | string | <--> | flavour_id | yes | string |
flavour_description | yes | string | <--> | flavour_description | yes | string |
vnf_profile | no | tosca.datatypes.nfv.VnfProfile | <--> | vnf_profile | no | tosca.datatypes.nfv.VnfProfile |
mciop_profile | no | list of tosca.datatypes.nfv.MciopProfile | <--> | mciop_profile | no | list of tosca.datatypes.nfv.MciopProfile |
<SDC AID DM VF attributes that are inherited from org.openecomp.resource.abstract.nodes.VF> | ||||||
<the followings are being considered> | nf_function | no | string | |||
requirements | Yes | nf_role | no | string | ||
interfaces | yes | tosca.interfaces.nfv.VnfLcm | nf_type | no | string | |
nf_naming_code | no | string | ||||
nf_naming | no | org.openecomp.datatypes.Naming | ||||
availability_zone_max_count | no | integer | ||||
min_instances | no | integer | ||||
max_instances | no | integer | ||||
multi_stage_design | no | boolean | ||||
sdnc_model_name | no | string | ||||
sdnc_artifact_name | no | string | ||||
skip_post_instantiation_configuration | no | boolean (default true)
| ||||
controller_actor | no | string (default: SO-REF-DATA)
| ||||
Option B:
Define a new data type based on the tosca.nodes.nfv.VNF with SDC AID DM VNF data type attributes.
...
capabilities:
requirements:
SOL001 VNFD mapping to/from SDC AID DM VFD
...
<tosca.nodes.nfv.NsVirtualLink>
<tosca.datatypes.nfv.NsVlProfile>
<tosca.datatypes.nfv.ConnectivityType>
<tosca.datatypes.nfv.LinkBitrateRequirements>
<tosca.datatypes.nfv.NsVirtualLinkQos>
<tosca.datatypes.nfv.ServiceAvailability>
Current SDC VL
...
SOL001 PNF mapping to/from VL SDC AID DM
Table of Contents
...
Epic | User Story | Task | Description | Honolulu Plan? | JIRA | Size (S/M/L/XL) | Priority | ||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Support Onboard ETSI 3.3.1 SOL004 compliant VNF / CNF packages |
| Yes |
| 4 weeks for one designer | High | ||||||||||
Support for onboarding ETSI v3.3.1 SOL004 VNF CSAR Packages with minimum CNF enhancements from 4.1.1 |
source: Artifacts/helm/helm_charts.yaml
| Yes |
| High | |||||||||||
Determine the onboarding path based on manifest metadata |
| High | |||||||||||||
Create a new onboarding path for SOL004 3.3.1 VNF package |
| High | |||||||||||||
Support the SOL001 vnf_profile properties | SDC needs to support the SOL001 vnf_profile (toaca.databypes.nfv.VnfProfile) properties |
| High | ||||||||||||
Support for onboarding ETSI v3.3.1 SOL001 VNF Descriptors |
| Yes |
| High | |||||||||||
Determine the onboarding path based on metadata |
| ||||||||||||||
Create a new onboarding path for SOL001 VNFD 3.3.1 |
| ||||||||||||||
Support for onboarding ETSI v3.3.1 SOL001 VNF Descriptors with minimum CNF enhancements from 4.1.1 | SDC users need to onboard ETSI 3.3.1 with minimum CNF enhancements from 4.1.1
| Yes |
| High | |||||||||||
Support minimum CNF enhancements from 4.1.1 | Support the vnfd_type with CNF attributes from 4.1.1:
| ||||||||||||||
Extend the 3.3.1 VNFD onboarding path for CNF attributes | Extend the 3.3.1 VNFD onboarding logic for CNF attribute handling | ||||||||||||||
=========== | |||||||||||||||
Support for mapping of ETSI v3.3.1 SOL001 VNF Descriptor into SDC AID Data Model | Once SDC onboards an ETSI v3.3.1 SOL001 VNF Descriptor, SDC needs to map the ETSI v3.3.1 SOL001 VNF Descriptor into SDC AID Data Model
VNF Mapping:
VDU Mapping:
VF-Module Mapping (Stretch goal)
SDC supports Interface mapping to SDC AID DM for creating Service and connect VNF to external networking, etc. Capacity and requirement mapping won't be necessary in this release | Yes |
| Medium (VF-Module mapping is a stretch goal) | |||||||||||
Map VNF data type to SDC AID DM VF | Map VNF data type to SDC AID DM VF | ||||||||||||||
Map VDU data type to SDC AID DM VFC | Map VDU data type to SDC AID DM VFC | ||||||||||||||
Deduce VF-Module from VNFD Policies | Deduce VF-Module from VNFD Policies | ||||||||||||||
Map VNF Interfaces to SDC AID DM | Map VNF Interfaces to SDC AID DM | ||||||||||||||
Support for mapping of ETSI v3.3.1 SOL001 VNF Descriptor with minimum CNF enhancements from 4.1.1 into SDC AID Data Model | Once SDC onboards an ETSI v3.3.1 SOL001 VNF Descriptor with CNF enhancements, SDC needs to map the ETSI v3.3.1 SOL001 VNF Descriptor with minimum CNF enhancements from 4.1.1 into SDC AID Data Model
| Yes |
| medium | |||||||||||
Map VNF with CNF properties to SDC AID DM | |||||||||||||||
Map VDU with CNF properties to SDC AID DM | |||||||||||||||
Map virtualCPD to SDC AID DM | |||||||||||||||
Map MCIOP to SDC AID DM | |||||||||||||||
Support for editing ETSI v3.3.1 SOL001 VNF / CNF Descriptor | SDC users should be able to edit onboarded ETSI v3.3.1 SOL001 VNF Descriptors
Note: should we reflect the changes to original vendor packages in ETSI_PACKAGE directory??? need to think about impact... SDC generates a new digital signature for the package and distributes it to ETSI Catalog Manager. | Yes |
| medium | |||||||||||
Enhance SDC UI for editing SOL001 VNF / CNF descriptor properties | Enhance SDC UI for editing SOL001 VNF / CNF descriptor properties | ||||||||||||||
Design ETSI SOL007 compliant Network Service Descriptor packages |
| Yes |
| 1 week for one designer | High | ||||||||||
Support for designing an ETSI SOL001 v3.3.1 compliant Network Service that can be deployed with an ETSI compliant NFVO | SDC users need to design an ETSI SOL001 v3.3.1 compliant Network Service that can be deployed with an ETSI compliant NFVO
| Yes |
| High | |||||||||||
Enhance SDC design for creating v3.3.1 NS | Enhance SDC design for creating v3.3.1 NS | ||||||||||||||
Generate v3.3.1 SOL007 NS package | Generate v3.3.1 SOL007 NS package
| ||||||||||||||
Compose of one or more VNFs and the Virtual Links that connect them | SDC users need to compose one or more VNFs and the Virtual Links that connect them in NS
Note: cover the VNF version validation... SAP descriptor has a version... | Yes |
| High | |||||||||||
Enhance SDC to compose v3.3.1 VNFs and VLs for v3.3.1 NS | Enhance SDC to allow compose v3.3.1 VNFs and VLs for v3.3.1 NS | ||||||||||||||
Validate NSD and VNFD version match | Validate NSD and VNFD version match
| ||||||||||||||
Support for compose VNFs with CNF enhancements | SDC users need to compose VNFs with CNF enhancements
| Yes |
| High | |||||||||||
Enhance SDC to compose v3.3.1 VNFs with CNF enhancements | Enhance SDC to compose v3.3.1 VNFs with CNF enhancements | ||||||||||||||
Support for mapping of ETSI v3.3.1 SOL001 Network Service Descriptor in the SOL007 package into SDC AID Data Model | SDC needs to support for mapping of ETSI SOL001 Network Service Descriptor in the SOL007 package into SDC AID Data Model
| Yes |
| Medium | |||||||||||
Map v3.3.1 NSD to SDC AID DM | Map v3.3.1 NSD to SDC AID DM | ||||||||||||||
Suport Interfaces | Suport NS Interfaces to SDC AID DM | ||||||||||||||
Support design of Service templates, leveraging NSDs | SDC users need to support design of Service templates, leveraging NSDs ONAP service references NSDs... | Yes |
| Medium | |||||||||||
Compose Service Templates referencing NSDs | Compose Service Templates referencing NSDs | ||||||||||||||
Design Nested/Hierarchical ETSI SOL001 v3.3.1 Network Service Descriptor package |
| No |
| N/A | |||||||||||
Compose of zero or more VNFs and one or more nested Network Services and the Virtual Links that connect them | SDC users need to compose zero or more VNFs and one or more nested Network Services and the Virtual Links that connect them | No |
| N/A | |||||||||||
Support for using VNFs with CNF enhancements | Support design of Service templates, leveraging NSDs | No |
| N/A | |||||||||||
Onboard Prototype Package based on ETSI IFA011 v4.1.1 supporting containerized VNF (CNF) packages |
| No |
| N/A | |||||||||||
Support for onboarding Prototype v4.1.1 CSAR Packages | SDC needs to support onboarding prototype v4.1.1 CSAR packages with CNF artifacts and metadata | No |
| ||||||||||||
Support for onboarding Prototype v4.1.1 VNF/CNF Descriptor | SDC needs to support onboarding prototype v4.1.1 VNF/CNF descriptor | No |
| ||||||||||||
Support for mapping of Prototype v4.1.1 VNF/CNF Descriptor into SDC AID Data Model | SDC needs to support mapping of prototype v4.1.1 VNF/CNF Descriptor into SDC AID Data Model | No |
| ||||||||||||
Support for using a Prototype v4.1.1 VNF in an ETSI Network Service | SDC needs to support for a prototype v4.1.1 VNF/CNF in an ETSI network Service | No |
| ||||||||||||
Onboard ETSI 3.3.1 SOL004 compliant PNF packages | Executive Summary - Enable a vendor provided ETSI 3.3.1 SOL004 compliant PNF package including an ETSI SOL001 PNF Descriptor to be onboarded into ONAP for composition into an ONAP Service Business Impact - Enables operators and service providers to use same ETSI compliant PNF packages with ONAP and existing NFVO. Industry compatibility. Business Markets - All operators that are currently using ETSI packages to deploy PNFs Funding/Financial Impacts - Reduction in operations expense from using industry standard PNF packaging. Reduction in capital expense from vendors using a single packaging methodology. Organization Mgmt, Sales Strategies -There is no additional organizational management or sales strategies for this requirement outside of a service providers "normal" ONAP deployment and its attendant organizational resources from a service provider. | No |
| N/A | |||||||||||
SDC supports onboarding of the 3.3.1 SOL004 PNF package includes SOL001 PNFD |
| No |
| N/A | |||||||||||
Support for mapping of ETSI v3.3.1 SOL001 PNF Descriptor into SDC AID Data Model | SDC needs to support 3.3.1 SOL001 PNFD Mapping to SDC AID DM | No |
| N/A | |||||||||||
Onboard ETSI SOL007 compliant Network Service Descriptor packages | Executive Summary - Onboard an ETSI SOL007 v3.3.1 compliant (Link to ETSI SOL007 v3.3.1) Network Service Descriptor package including an ETSI version 3.3.1 SOL001 Network Service Descriptor (NSD) to be onboarded into ONAP for composition into an ONAP Service or deployment using an ETSI compliant NFVO.
Business Markets - All operators and service providers that are developing ETSI compatible Network Services Funding/Financial Impacts - Reduction in operations expense from using industry standard NSD packaging. Organization Mgmt, Sales Strategies -There is no additional organizational management or sales strategies for this requirement outside of a service providers "normal" ONAP deployment and its attendant organizational resources from a service provider. | No |
| N/A | |||||||||||
Support onboarding for Cataloging and Preserving the original SOL007 package | SDC users need to support onboarding for Cataloging and Preserving the original SOL007 package (Link to ETSI SOL001 v3.3.1) | No |
| N/A | |||||||||||
Support for onboarding of the SOL007 v3.3.1 compliant NSD package including SOL001 NSD that includes references to other NSDs for composition into ONAP Service | SDC users need to support for onboarding of the SOL007 v3.3.1 compliant NSD package including SOL001 NSD that includes references to other NSDs for composition into ONAP Service | No |
| N/A | |||||||||||
Support ETSI Package Security and validation | ONAP supports vendor ETSI 3.3.1Package Security and validation
| Yes |
| 4 weeks for one designer | High | ||||||||||
| ONAP SDC supports ETSI 3.3.1 SOL004 VNF/PNF Package security | Yes | |||||||||||||
| ONAP SDC supports ETSI 3.3.1 SOL007 NS Package security | Yes |
| High | |||||||||||
Support of ETSI Package Validation | VNF SDK will support ETSI package validation for VNF and NS | TBD | N/A | ||||||||||||
VNF SDK will support ETSI VNF package pre-onboarding for validation | VNF SDK will support ETSI VNF package pre-onboarding for validation | TBD | N/A | ||||||||||||
VNF SDK will support ETSI NS package pre-onboarding for validation | VNF SDK will support ETSI NS package pre-onboarding for validation | TBD | N/A |
...
- Enhancement (Ericsson contribution) was made to the SDC Dublin to support SOL004 PNF/VNF onboarding with .zip and .csar file extensions.
- SDC VSP and Resource csar files have the ETSI_PACKAGE, which contains the original vendor VNF package.
- The VNFM and external NFVO use the original vendor VNF/NS packages.
- ONAP-ETSI Catalog Manager will be changed for the location of the original vendor package.
- SOL007 NS onboarding will follow the same procedure; i.e., storing the vendor SOL007 NS package into the ETSI_PACKAGE directory.
- SDC VSP and Resource csar files have the ETSI_PACKAGE, which contains the original vendor VNF package.
- In Guilin, the ONBOARDED_PACKAGE directory is changed to the ETSI_PACKAGE directory.
- At onboarding, SDC checks the file extension and performs the following procedures
- If the file is .zip, SDC unzips
- If it has .cert & .cms, it is a package with security and security validation will be performed.
- If it does not include .cert & .cms, it is an existing Heat template onboarding, and SDC follows the Heat template onboarding procedure
- If the file is .zip, SDC unzips
- If the file is .csar, it is a package without security.
- Next, SDC will check the TOSCA.meta file.
- If it contains SOL004v2.x.1 keywords, the package will be handled as SOL004v2.x.1. In the Guilin release, v3.3.1 will be supported.
- Otherwise, it will be handled as existing TOSCA (non-SOL004) package onboarding which will not have the ETSI_PACKAGE artifact.
NS Onboarding Design
...
Gliffy | ||||||
---|---|---|---|---|---|---|
|
- SOL004 VNF/PNF and SOL007 NS Packages are onboarded to SDC.
- SDC creates its Resource CSAR by adding ONAP-specific files and metadata according to SDC procedure.
- For VNF onboarding, SOL001 VNFD is mapped to SDC Data Model.
- For NS onboarding, SOL001 NSD is mapped to SDC Data Model. Note: the SDC NS Data Model would be SOL001 NSD-based.
- For PNF onboarding, SOL001 PNFD is mapped to SDC Data Model.
- The original SOL004 VNF/PNF and SOL007 NS packages will be stored in the ETSI_PACKAGE directory.
- SDC shall have a capability to design SOL007 NSDs and generates SOL007 NS packages
- Since SDC does not have a proper NS Model, it will follow SOL001 NSD.
- SDC embeds the Resource CSAR into its Service CSAR for distribution.
- After SDC validates the onboarded packages, the Service CSAR is distributed.
- SDC sends the package notification to DMaaP for its package notification subscribers.
- ETSI Catalog Manager receives the package notification from SDC.
- ETSI Catalog Manager queries SDC for the SDC CSAR.
- ETSI Catalog Managers examines the SDC CSAR. If the SDC CSAR contains the ETSI_PACKAGE directory, it extracts the SOL004/SOL007 packages from the directory.
- ETSI Catalog Manager stores the SOL004/SOL007 packages to its Catalog Database.
- ETSI Catalog Manager provides APIs for the SOL003/SOL005 Adapters to distribute the packages to SVNFM/NFVO.
- ETSI Catalog Manager queries SDC for the SDC CSAR.
Design NS
NSD Structure
SDC supports NSD design that meets the following requirements.
...
- SDC supports the following NSD Information Elements.
- SDC supports the netestedNsdId(s) for nested NSDs. (not for Guilin)
- SDC UI should be able to manage the NSD attributes.
- SDC supports the virtualLinkDesc(s) to define constituent VLs.
Use Cases for Guilin
...
- SDC should be able to reference the vCPE NSD from the E2E Service model.
- SDC should be able to reference all the constituent VNFs and VL(s).
<example>
- Test with vGW and VGMUX with a VL first.
...
- SDC supports NSVLDs that are defined in the ETSI IFA 014, as part of NS design.
- SDC UI should be able to handle the following VLD attributes.
VNFD Composition
...
The following depicts the VNFD information element.
SapD Composition
SapD fulfills the following information element.
Distribution
ETSI packages will be distributed from SDC to the ETSI Catalog Manager for other ONAP runtime components such as SO (SOL003/SOL005 Adapter) and VF-C.
...
ETSI Catalog Manager will interface with the SDC directly, without a help from ONAP SO.
Package Distribution Components Interactions
...
- Vendor SOL004/SOL007 VNF Package with certificate and signature is onboarded into SDC
- ZIP-format VNF package includes CSAR, Signature and Certificate
- SDC validates VNF package based on the certificate and signature
- SDC generates SDC internal model plus the vendor SOL004/SOL007 package CSAR and ZIP (with certificate and signature) – the supported format is TBD based on the security requirement
Package Security
...
Current Mapping Support (as of Frankfurt)
Note: AAI impacts are under discussion.
...
NSD Mapping to SDC AID DM
Initial Input
NSD Mapping to SDC AID DM
...
<tosca.datatypes.nfv.NsProfile>
SDC TOSCA Repository
SDC nfv-types
SDC nfv-types/NSD
...
capabilities:
requirements:
SOL001 VNFD mapping to/from SDC AID DM VFD
...
<tosca.nodes.nfv.NsVirtualLink>
<tosca.datatypes.nfv.NsVlProfile>
<tosca.datatypes.nfv.ConnectivityType>
<tosca.datatypes.nfv.LinkBitrateRequirements>
<tosca.datatypes.nfv.NsVirtualLinkQos>
<tosca.datatypes.nfv.ServiceAvailability>
Current SDC VL
...