Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.


R2 Video Session Recording

Model Design: R2 model design.wmv

Service Operation: VOLTE R2 operation.wmv


R2 Test Cases

80%60%60%

Test Case ID

Test Case Name

Conclusion (Pass/Fail)

Progress and Block Issue(s)


Lab infrastructure preparation: including hardware, VIMs, EMS, s-VNFM, PNFs / VNFs installation

100%

No external SDN controller

Huawei VNFM upgrade is complete

Huawei EMS upgrade is complete


Install ONAP and health check

100%


V00001

WindRiver OpenStack VIM Registration

100%


V00005

Vendors' SVNFMs Registration

100%


V00006

Vendors' EMSs Registration

100%


V00007

VoLTE VNFs Onboarding

100%


V00009

vIMS Service Creation

100%


V00013

VoLTE Service Instantiation

100%

Jira Legacy
serverSystem Jira
columnskey,summary,type,created,updated,due,assignee,reporter,priority,status,resolution
serverId4733707d-2057-3a0f-ae5e-4fd8aff50176
keySO-615
Jira Legacy
serverSystem Jira
columnskey,summary,type,created,updated,due,assignee,reporter,priority,status,resolution
serverId4733707d-2057-3a0f-ae5e-4fd8aff50176
keyUSECASEUI-113

Jira Legacy
serverSystem Jira
columnskey,summary,type,created,updated,due,assignee,reporter,priority,status,resolution
serverId4733707d-2057-3a0f-ae5e-4fd8aff50176
keySO-619
Jira Legacy
serverSystem Jira
columnskey,summary,type,created,updated,due,assignee,reporter,priority,status,resolution
serverId4733707d-2057-3a0f-ae5e-4fd8aff50176
keySO-624
Jira Legacy
serverSystem Jira
columnskey,summary,type,created,updated,due,assignee,reporter,priority,status,resolution
serverId4733707d-2057-3a0f-ae5e-4fd8aff50176
keySO-630

Validated e2e service with the new SDC data model

V00014

System Performance and Alarm Monitoring

100%


V00015

VoLTE Auto-healing

100%

50%

Holmes AAI query failed due to MSB wrong aai service uri registration

Issues:

1) Unable to register a https aai service from MSB GUI. Workaround with command line registration

Jira Legacy
serverSystem Jira
columnskey,summary,type,created,updated,due,assignee,reporter,priority,status,resolution
serverId4733707d-2057-3a0f-ae5e-4fd8aff50176
keyMSB-198
Jira Legacy
serverSystem Jira
columnskey,summary,type,created,updated,due,assignee,reporter,priority,status,resolution
serverId4733707d-2057-3a0f-ae5e-4fd8aff50176
keyINT-521

2) VoLTE Policy fails to send restartvm request to VFC on ONSET event

Jira Legacy
serverSystem Jira
columnskey,summary,type,created,updated,due,assignee,reporter,priority,status,resolution
serverId4733707d-2057-3a0f-ae5e-4fd8aff50176
keyPOLICY-868

V00016

VoLTE Service Termination

100%

Jira Legacy
serverSystem Jira
columnskey,summary,type,created,updated,due,assignee,reporter,priority,status,resolution
serverId4733707d-2057-3a0f-ae5e-4fd8aff50176
keySO-640

V00017

VoLTE Manual scaling

30%

Tested VNF scaling from SVNFM

100%

Scaling works, but job status update has some issues.

Jira Legacy
serverSystem Jira
columnskey,summary,type,created,updated,due,assignee,reporter,priority,status,resolution
serverId4733707d-2057-3a0f-ae5e-4fd8aff50176
keyUSECASEUI-122


Service Instantiation Flow

...

Test Step IDProgressNotes
2.1Pass
2.2Pass

resolved by

Jira Legacy
serverSystem Jira
columnskey,summary,type,created,updated,due,assignee,reporter,priority,status,resolution
serverId4733707d-2057-3a0f-ae5e-4fd8aff50176
keyUSECASEUI-116


2.3Pass

resolved by

Jira Legacy
serverSystem Jira
columnskey,summary,type,created,updated,due,assignee,reporter,priority,status,resolution
serverId4733707d-2057-3a0f-ae5e-4fd8aff50176
keySO-619

2.4Pass

blocked by

Jira Legacy
serverSystem Jira
columnskey,summary,type,created,updated,due,assignee,reporter,priority,status,resolution
serverId4733707d-2057-3a0f-ae5e-4fd8aff50176
keySO-624

2.5Pass
2.6Pass
2.7Pass
2.8Partially passedPassHuawei SBC passed; Nokia CSCF failed due to some parameter missing from VNFD. Will design a new service with SBC only to test out ONAP features, in the meantime, Nokia will fix VNFDpassed
2.9Partially passedPassHuawei SVNFM passed; Nokia's has notand Nokia SVNFMs passed
2.10FailedVFC failed to insert vserver record to aai due to non-existing path2.11Pass2Pass
2.11Pass
2.12Pass

Auto Healing Flow

Image Added

http://13.82.90.118/EtherPlant/src/?http://13.82.90.118:9001/p/autoHealing


Code Block
titleAutoHealing
collapsetrue
@startuml
Title Auto Healing\n

Participant "DCAE" as DCAE
Participant "Holmes" as Holmes
Participant "VFC" as VFC
Participant "Policy" as Policy
Participant "AAI" as AAI
Participant "MultiVIM" as MultiVIM
Participant "3rd VNFM" as SVNFM
Participant "3rd EMS" as EMS

autonumber 3.1 1 "."
MultiVIM -> DCAE : Report VM event
DCAE -> Holmes : Forward VM event to Holmes
EMS -> VFC : Report VNF event
VFC -> DCAE : Forward VNF event to DCAE
DCAE -> Holmes : Forward VNF event to Holmes
Holmes -> AAI : Query vserver info
Holmes -> Holmes : Event correlation 
Holmes -> Policy : Send DCAE_CL_OUTPUT event
Policy -> AAI : Query service instance info
Policy -> VFC : Send closed loop healing action
VFC -> SVNFM : Send healing action
VFC -> SVNFM : Job status

@enduml



Test Step IDProgressNotes
3.1Pass
3.2Pass
3.3Pass
3.4Pass
3.5Pass
3.6Pass
3.7Pass
3.8Pass

Jira Legacy
serverSystem Jira
columnskey,summary,type,created,updated,due,assignee,reporter,priority,status,resolution
serverId4733707d-2057-3a0f-ae5e-4fd8aff50176
keyHOLMES-134

3.9Pass
3.10Pass

Issue: Policy doesn't send healing request to VFC, see

Jira Legacy
serverSystem Jira
columnskey,summary,type,created,updated,due,assignee,reporter,priority,status,resolution
serverId4733707d-2057-3a0f-ae5e-4fd8aff50176
keyPOLICY-868

3.11Pass
3.12Pass

Manual Scaling with VFC Flow

...

Manually tested VNF scaling from SVNFM
Test Step IDProgressNotes
1Pass
2Pass
3Pass
4Pass
5Pass
6Pass
7Pass
8Pass
9Pass
10Pass