Test Results @CMCC lab
Image Added
Category: External System Registration
V00001: WindRiver OpenStack VIM Registration
...
Test Case Id | V00006 |
Test Case Name | Vendors' EMSs Registration |
Description | Register all VNF vendors' EMSs |
Release | Amsterdam |
Preconditions | - All VNF vendor's EMS have been installed and configured
|
Testing Steps | - Register all vendors' EMSs using ONAP ESR GUI with the needed information (IP, port, authentication information, etc)
|
Expected Results | - All EMSs are registered successfully with ONAP
- All EMSs information is stored correctly in ONAP
|
Actual Results |
|
Conclusion (Pass/Fail) |
|
Testing Lab | CMCC OpenLab |
Tester Name |
|
Category: VNF Onboarding and Service Creation
V00007: VoLTE VNFs Onboarding
...
V00010: WAN Resource Onboarding (Need to finalize overlay and underlay are seperate VL resourcesUnderlay and Overlay templates are preloaded into SDC, this test case can be removed if not needed anymore)
Test Case Id | V00010 |
Test Case Name | WAN Resource Onboarding |
Description | This test onboards WAN resource using SDC |
Release | Amsterdam |
Preconditions | - WAN underlay network template (.yaml) has been defined and packaged in a CSAR file
- WAN overlay network template (.yaml) has been defined and packaged in a CSAR file
|
Testing Steps | - In SDC create a VL resource and upload WAN underlay network CSAR file. Make sure controllerInfo property is set to SDNC in the template
- In SDC create a VL resource and upload WAN overlay network CSAR file. Make sure controllerInfo property is set to SDNC
|
Expected Results | - WAN underlay network resource onboarded successfully and shown in catalog
- WAN overlay network resource onboarded successfully and shown in catalog
|
Actual Results |
|
Conclusion (Pass/Fail) |
|
Testing Lab | CMCC OpenLab |
Testing Date |
|
Tester Name |
|
...
Test Case Id | V00012 |
Test Case Name | Closed loop configuration |
Description | This test uses CLAMP to configure closed loop for VoLTE. There are 4 configurations: - Provisional rules for Policy
- Correlation rules for Holmes
- Holmes microservice Blueprint for DCAE
- VES configuration ?(in R1, there is no configuration needed)
|
Release | Amsterdam |
Preconditions | - DCAE template has been imported (R1 SDC doesn't support DCAE template design)
- Holmes blueprint has been imported
- Holmes correlation rules have been defined
|
Testing Steps | - In CLAMP, choose VNF SPGW and events (VNF Fault and VM Fault) to monitor
- Bring up CLAMP configuration policy GUI and copy Holmes correlation rules in it
- Bring up CLAMP provisional policy GUI and define healing provisional policy
- Save the configuration
|
Expected Results | - Closed loop template and blueprint for Holmes are distributed to DCAE
- Configuration policy has been distributed to DCAE
- Provisional policy has been distributed to Policy engine
|
Actual Results |
|
Conclusion (Pass/Fail) |
|
Testing Lab | CMCC OpenLab |
Testing Date |
|
Tester Name |
|
Category: Service Instantiation and Monitoring
V00013: VoLTE Service Instantiation
...
Test Case Id | V00014 |
Test Case Name | System Performance and Alarm Monitoring |
Description | This test uses Usecase UI GUI to monitor system performance and event |
Release | Amsterdam |
Preconditions | - VoLTE service has been instantiated
- Closed loop for VoLTE has been configured and started
|
Testing Steps | - ONAP user uses Usecase UI GUI to check system performance, such as CPU, memory and disk usage
- ONAP user views the VNF alarms collected by ONAP
|
Expected Results | - System performance (including system CPU, memory and disk usage) is shown on ONAP Usecase UI GUI
- VNF alarms, specified in CLAMP for the closed loop, are shown in Usecase UI GUI
|
Actual Results |
|
Conclusion (Pass/Fail) |
|
Testing Lab | CMCC OpenLab |
Testing Date |
|
Tester Name |
|
Category: Closed Loop
V00015: VoLTE Auto-healing
Test Case Id | V00015 |
Test Case Name | VoLTE Auto-healing |
Description | This test covers the closed loop with alarm correlation and auto-healing |
Release | Amsterdam |
Preconditions | - VoLTE service has been instantiated
- VoLTE closed loop has been configured and started
- SPGW VNF supports event generation
- VNF guest OS supports event generation
- MultiVIM supports event collection from guest OS and event forwarding
|
Testing Steps | - Use Robot test script to Manually shutdown standby MPU VM inside SPGW VNF. This should trigger the VNF and VIM to generate alarms
|
Expected Results | - EMS collects standby MPU offline event from SPGW VNF and sends the event to VFC
- MultiVIM doesn't receive heartbeat event from standby MPU guest OS for a period of time and triggers alarm which is sent to DCAE VES collector
- Holmes receives MPU offline events
- Holmes receives MPU guest OS heartbeat missing events
- Holmes does correlation of the two types of events and generate one signature event and sends it to Policy
- Policy triggers provisional policy and healing action is sent to VFC
- VFC uses SVNFM driver to heal standby MPU VM
- Standby MPU is healed
- Clear event is sent from SPGW VNF about standby MPU back online
- Heartbeat from standby MPU VM is received by MultiVIM and clear event is sent by MultiVIM about heartbeat recovery
- Holmes does the event correlation and sends Clear signature event to Policy
- Policy stops the healing action
|
Actual Results |
|
Conclusion (Pass/Fail) |
|
Testing Lab | CMCC OpenLab |
Testing Date |
|
Tester Name |
|
Category: Service Termination
V00016: VoLTE Service Termination
...