We are working on the Guilin planning: SDN-R Release Guilin
Please check out for updates and propose suggest additional topics you would like to address as comments to the wiki.
...
Time | Item | Who | Notes |
---|
00:00 | Admin | | Next meeting: 2020-05-13 |
00:05 | Integration | s.silvius | Experience about ONAP SDN-R A1 Adapter with and O-RAN-SC A1-Policy-Agent |
00:33 | Configuration & Persistency Service | @all | Discussion about Messageflows for CMNotify from VES-Collector to "RuntimeDB".
- Options:
- RuntimeDB listen on DMaaP as described:
ARCHCOM: InfoFlow - RunTime Config DB Information Flow#3.1FLOW1:VESInformationFlowCMNotify-WritingtoRunTimeDB - Fits to the overall ONAP architecture
- SDN-R listen on DMaaP and a function or µService updates RuntimeDB
- Comment: such function or µService for sure under the responsibility for RuntimeDB - SDN-R is not involved - however such function or µService coudl or could not deploy together with SDN-R → this could be a deployment option and would need to be configured by OOM helm charts.
- This option is not discussed and specificed and does not fit much into the ONAP architecture.
Discussion about Messageflow from "RuntimeDB" to NetConf Servers
Info found after the meeting (not discussed)
01:19 | The End | Thanks!! | 00:00 | Yang error messages - RFC7950
yang defined error-messages are supported for the following yang statements.
- 7.5.4. The must's Substatements
- 9.2.4.1. The range's Substatements
- 9.4.4.1. The length's Substatements
- 9.4.5.1. The pattern's Substatements
Example:
[...]
must "./ssh-connections + ./tls-connections <= 100" {
error-message "The total number of connections (SSH + TLS) needs to be less than or equal with 100.";
}
[...]
Result in odl-restconf-nb-baermann
{
"errors": {
"error": [
{
"error-type": "application",
"error-tag": "operation-failed",
"error-message": "Commit of transaction org.opendaylight.netconf.sal.connect.netconf.sal.tx.WriteCandidateRunningTx@2aa1fb85 failed",
"error-info": "RemoteDevice{NTS-manager}:RPC during tx failed. The total number of connections (SSH + TLS)
needs to be less than or equal with 100."
}
]
}
}Result in odl-restconf-nb-RFC8040
{
"errors": {
"error": [
{
"error-type": "application",
"error-message": "RemoteDevice{NTS-manager}:RPC during tx failed. The total number of connections (SSH + TLS)
needs to be less than or equal with 100.",
"error-tag": "operation-failed",
"error-info": "TransactionCommitFailedException{message=Commit of transaction
org.opendaylight.netconf.sal.connect.netconf.sal.tx.WriteCandidateRunningTx@adb0c99 failed,
errorList=[RpcError [message=Commit of transaction
org.opendaylight.netconf.sal.connect.netconf.sal.tx.WriteCandidateRunningTx@adb0c99 failed,
severity=ERROR, errorType=APPLICATION, tag=operation-failed, applicationTag=null, info=null,
cause=NetconfDocumentedException{message=RemoteDevice{NTS-manager}:RPC during tx failed. The total number
of connections (SSH + TLS) needs to be less than or equal with 100., errorType=APPLICATION,
errorTag=OPERATION_FAILED, errorSeverity=ERROR, errorInfo={}}]]}"
}
]
}
}
00:00 | Geo-redundancy >> goes to next meeting | | Overview Impact on SDN-R -- see: SDN-R Geo-Redundancy20 |
Action items