Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

Introduction:

...

Attribute

Qualifier

#

Content

Description

deploymentItemId

M

1

Identifier

The identifier of this deployment item

artifactType

M

1

String

Specifies the artifact type. One of following values can be chosen: "helm_chart", "helmfile", "crd", "terraform"

artifactId

M

1

String

Reference to a DeploymentArtifact. It can refer to URI or file path. 

deploymentOrder

M

0..1

Integer

Specifies the deployment stage that the DeploymentArtifact belongs to. A lower value specifies that the DeploymentArtifact belongs to an earlier deployment stage, i.e. needs to be installed prior to DeploymentArtifact with higher deploymentOrder values. If not specified, the deployment of the DeploymentArtifact can be done in arbitrary order and decided by the orchestrator.

lifecycleParameters

M

0..N

String

The list of parameters that can be overridden at deployment time (e.g., the list of parameters in the values.yaml which can be overridden at deployment time)

Note 1: All cloud native CNF resource IM is specified by particular cloud native specifications. K8s document is an example.

asdExtCpd Information Element

AttributeQualifierCardinalityContentDescription
idM1StringThe identifier of this extCpdData
descriptionM1StringDescribes the service exposed.
virtualLinkRequirementM1..NStringRefers in an abstract way to the network or multiple networks that the ExtCpd shall be exposed on (ex: OAM, EndUser, backhaul, LI, etc). The intent is to enable a network operator to take decision on to which actual VPN to connect the extCpd to. NOTE 1.
networkInterfaceRealizationRequirementsM0..1datatype.networkInterfaceRealizationRequirementsDetails container implementation specific requirements on the NetworkAttachmentDefinition to . See NOTE 2 & 3.
inputParamMappingsM0..1datatype.extCpd.ParamMappingsInformation on what parameters that are required to be provided to the deployment tools for the asdExtCpd instance.
resourceMappingM0..1StringKubernetes API resource name for the resource manifest as specified e.g. in helm.chart for the service, ingress or pod resource declaring the network interface. Enables, together with knowledge on namespace, the orchestrator to lookup the runtime data related to the extCpd.

NOTE 1: Corresponds more or less to a virtual_link requirement in ETSI NFV SOL001.
NOTE 2: Applies only for ExtCpds representing secondary network interfaces in a pod.
NOTE 3: Several ExtCpd may refer to same additional network interface requirements.

networkInterfaceRealizationRequirements Information Element

AttributeQualifierCardinalityContentDescription
trunkModeM0..1”false” | ”true”If not present or  set to”false”, means that this interface shall connect to single network. If set to ”true” then the network interface shall be a trunk interface (connects to multiple VLANS).
ipamM0..1"infraProvided", "orchestrated", "userManaged"The default value ("infraProvided") means that the CNI specifies how IPAM is done and assigns the IP address to the pod interface. 
interfaceType​M0..1

"kernel.netdev", "direct.userdriver", "direct.kerneldriver", "direct.bond", "userspace

This attribute is applicable for passthrough and memif interfaces. Value default value is ”kernel.netdev”.​ 
interfaceOptionsM0..N

"virtio",
"memif"

Alternative vNIC configurations the network interface is verified to work with.

interfaceRedundancyM0..1"infraProvided", "activePassiveBond", "activeActiveBond", "activePassiveL3", "activeActiveL3",
 ”bondCni”,
"Left", "Right"

”infraProvided” means that the application sees one vNIC but that the infrastruture provides redundant access to the network via both switch planes. ”Left” and ”right” indicates a vNIC connected non-redundantly to the network via one specific (left or right) switchplane. All other attributes indicates a mated vNIC pair in the Pod, one connecting to the network via left switchplane and the other connecting to the network via the right switchplane, and with application using them together as a redundant network interface using a particular redundancy method that need to be accomodated in the node infrastructure.
"activeActiveBond": The bonded left/right links must be part of a multi-chassis LAG in active-active mode
"activePassiveBond": Interfaces bonded in active-passive mode in the application with move of bond MAC address. No specific requirements on DC fabric.
"activePassiveL3":  Move of application IP address
"activeActiveL3": Anycast/ECMP
”bondCni” ; the mated pair network interfaces are used via a 3rd bond cni based network interface.

nicOptionsM0..N"examples": ["i710", "mlx-cx5v"]

nics a direct user space driver the application is verified to work with. Allowed values from ETSI registry.


datatype.ExtCpd.ParamMappings Information Element

...