This page explains the manual configurations required for setting up E2E network slicing use case - option 1.
...
SDC UUI: https://sdc.api.fe.simpledemo.onap.org:30207/sdc1/portal#!/dashboard
Refer for Template Design for Option 1 respective template creation and distribution.
2.UUI Configuration
Configure CST template UUID and Invariant UUID in slicing.properties file of uui-server microservice
...
Install config DB application in a separate VM. MariaDB container should be up and running to access the config DB APIs.
Refer https://wiki.onap.org/display/DW/Config+DB+setup for configDB setup for configDB setup. Latest source is available at Image versions, preparation steps and useful info-Config DB Preload Info Section.
Necessary RAN network functions data are preloaded in config DB while booting the maria DB container.
9. SDNC
Install SDNC using OOM charts and the below pods should be running. As ran-slice RPCs are not visible in the latest SDN-C image, use the image version 2.1.0 for sdnc-image and dmaap listener. Manually, load the RANSlice DGs like below:
- Copy the DG XMLs from /distribution/platform-logic/ran-slice-api/src/main/xml (gerrit repo) to /opt/onap/sdnc/svclogic/graphs/ranSliceapi(sdnc container)
- Install the DGs : a) Navigate to /opt/onap/sdnc/svclogic/bin (Sdnc container) (b) Run ./install.sh
SDNC Pods
|
...