Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

Gliffy
macroId22885eaa-5a4d-40b6-9d8a-cb56aa56aa81
nameeMBB-mIOT-NE Enterprise Slice Instances
pagePin2

Example of adding a new URLLC Slice including Transport

Gliffy
size600
nameAdded SFO Site
pagePin2

  1. CSMF(SFO URLLC) => NSMF (SFO URLLC Service Profile)
  2. NSMF creates SFO URLLC Slice Profile
  3. NSMF => NSSMF (SFO URLLC Slice Profile)
  4. NSSMF Matches SFO URLLC Slice Profile to:
    1. SFO Site (Edge Network Slice Subnet Service)
    2. C (Central Network Slice Subnet Service)
    3. Nationwide Slice Subnet Service ("Data Network" and "Control Network")
    4. SFO Site Radio Links
  5. NSSMF create Configuration data and Slice Profile for each instance:
    1. SFO (Edge) Slice Profile
    2. C (Central SFO URLLC) Slice Profile
    3. Nationwide SFO URLLC Slice Profile
  6. NSSMF Identifies existing Nationwide NSSI and C NSSI with enough capacity for SFO URLLC Slice Profile but needs to instantiate new Edge NSSI:
    1. Existing Nationwide NSSI (Data Network and Control Network)
    2. Existing C NSSI
    3. New SFO URLLC NSSI
  7. NSSMF => NSSMF (C, Central SFO URLLC Slice Profile)
    1. NSSMF(C) configures Central VNFs(C Central SFO URLLC data)
    2. NSSMF(C) update C NSSI (Capacity Available, Capacity Allocated )
  8. NSSMF => NSSMF(Nationwide, Nationwide SFO URLLC Slice Profile)
    1. NSSMF(Nationwide, Complete)  configures Nationwide SFO URLLC Data Network and Control Network
    2. NSSMF(Nationwide, Complete) updates Nationwide NSSI (Capacity Available, Capacity Allocated )
  9. NSSMF => NSMF(SFO, Edge)
    1.  NSSMF (SFO, Edge)  => SO (Edge Network Slice Service (SFO Parameters)
    2. SO => NFVO (Edge Network Slice Network Service)
      1. NFVO Configures "internal RAN Network"
      2. NFVO => NFVO (RAN NS)
        1. NFVO (RAN) sets up network connection points (FH Links, Internal RAN and Control networks) and works with VNFM(s) to Instantiate VNFs and CNFs
      3. NFVO => NFVO (UP NS)
        1. NFVO (UP) sets up network connection points (Internal RAN, Control and Data networks) and works with VNFM(s) to Instantiate VNFs and CNFs
    3. NSSMF configures SFO Edge VNF/CNF/PNFs(SFO,  SFO URLLC data)
    4. NSSMF registers SFO Edge NSSI (Capacity Available, Capacity Allocated ) in A&AI
  10. NSSMF registers SFO URLLC NSSI (Capacity Available, Capacity Allocated ) with A&AI
  11. NSMF registers SFO URLLC Slice
  12. CSMF completes