Since the NS can be composed VNFs, CNFs, PNFs and nested NSs, the ETSI NS model is well suited to describe the hierarchical structure of 3GPP Network Slice Subnets.
![ServiceDesc.png](https://lf-onap.atlassian.net/wiki/plugins/servlet/confluence/placeholder/unknown-attachment?locale=en_GB&version=2)
![3GPP TS.541 Slice Model 3GPP TS.541 Slice Model](https://lf-onap.atlassian.net/wiki/download/thumbnails/16447595/image2020-10-23_13-25-27.png?version=1&modificationDate=1603473928000&cacheVersion=1&api=v2&height=400)
Design Time:
Gliffy |
---|
macroId | 456c09dd-3291-460c-8224-5d153a608d89 |
---|
name | Central 5G Service and Network Service Descriptors |
---|
pagePin | 8 |
---|
|
Gliffy |
---|
name | UP Service and Network Service Descriptors |
---|
pagePin | 3 |
---|
|
Gliffy |
---|
macroId | d2d7af96-01a3-4d55-950c-3d86c4206e1e |
---|
name | RAN Service and Network Service Descriptor |
---|
pagePin | 4 |
---|
|
...
- Onboard 5G Core NFs (NRF, PCF, UDM, AUSF, NEF, AMF, SMF, UPF) into SDC
- Onboard RAN NFs (vCU, vDU) insto SDC
- In SDC, design a "Central" Network Service composed of
- "central" NFs (NRF, PCF, UDM, AUSF, NEF)
- Virtual Link (Control Network) for the SBA interface
- SAP(s) for all of the exposed entry points
- SDC distribute the resulting SOL007 NS package to the ETSI Catalog (and any one else interested, SO??)
- In SDC, design a "User Plane" Network Service composed of:
- "user plane" NFs (AMF, SMF, UPF)
- Virtual Link (Control Network) for the SBA interface
- Virtual Link (RAN Network) for the interface to the RAN components
- Virtual Link (Data Network) for the (external) data/internet interface
- SAP(s) for all of the exposed entry points
- SDC distribute the resulting SOL007 NS package to the ETSI Catalog (and any one else interested, SO??)
- In SDC, design a "RAN" Network Service composed of:
- "RAN" NFs (CU, DU)
- Virtual Link (Control Network) for the SBA interface
- Virtual Link (RAN Network) for the interface to the RAN components
- SAP(s) for all of the exposed entry points
- SDC distribute the resulting SOL007 NS package to the ETSI Catalog (and any one else interested, SO??)
- In SDC, design a "Complete" Network Service composed of:
- Scalable reference to the RAN NS
- Scalable reference to the UP NS
- Scalable reference to the RAN NS
- SDC distribute the resulting SOL007 NS package to the ETSI Catalog (and any one else interested)
- In SDC, Design a "Central" Service composed of
- A reference to the "Central" Network Service
- A CDS blueprint (CBA) for configuring the "Central" Service
- Behavioral policies for the "Central" Service
- SDC distribute the resulting "Central" Service package
- In SDC, Design a "User Plane" Service composed of
- A reference to the "UP" Network Service
- A CDS blueprint (CBA) for configuring the "UP" Service
- Behavioral policies for the "UP" Service
- SDC distribute the resulting "UP" Service package
- In SDC, Design a "RAN" Service composed of
- A reference to the "RAN" Network Service
- A CDS blueprint (CBA) for configuring the "RAN" Service
- Behavioral policies for the "RAN" Service
- SDC distribute the resulting "RAN" Service package
- In SDC, Design a "Complete" Service composed of
- A reference to the "Complete" Network Service
- A CDS blueprint (CBA) for configuring the "Complete" Service
- Behavioral policies for the "Complete" Service
- SDC distribute the resulting "Complete" Service package
Runtime
Starting state:
- SOL004 Packages for Central, UP and RAN NFs in the ETSI Catalog
- SOL007 Packages for Central, UP, RAN and Complete NSs in the ETSI Catalog
- Service Packages Central, UP, RAN, and Complete NSs in SO Catalog
- Policies available in DCAE
- CBAs in CDS
- VIM & CISM regions (NE, SE, S, C, N, NW, SW) in A&AI
- 6 RAN/UP Sites and one Central Site available and registered in A&AI
Instantiate nationwide eMBB Slice :
- CSMF(eMBB Nationwide) => NSMF (eMBB Nationwide Service Profile)
- NSMF creates eMBB Nationwide Slice Profile
- NSMF => NSSMF (eMBB Nationwide Slice Profile)
- NSSMF Matches eMBB Slice Profile to:
- NE (UP Network Slice Subnet Service, RAN Network Slice Subnet Service)
- SE (UP Network Slice Subnet Service, RAN Network Slice Subnet Service)
- S (UP Network Slice Subnet Service, RAN Network Slice Subnet Service)
- C (Central Network Slice Subnet Service)
- N (UP Network Slice Subnet Service, RAN Network Slice Subnet Service)
- NW (UP Network Slice Subnet Service, RAN Network Slice Subnet Service)
- SW (UP Network Slice Subnet Service, RAN Network Slice Subnet Service)
- NSSMF create Configuration data and Slice Profile for each instance:
- NE (UP, RAN)
- SE (UP, RAN)
- S (UP, RAN)
- C (Central)
- N (UP, RAN)
- NW (UP, RAN)
- SW (UP, RAN)
- NSSMF Instantiate Network Slice Subnet Instances:
- NSSMF => NSSMF (C)
- NSSMF (C, Central) => SO (Central Network Slice Service (C Parameters)
- SO => NFVO (Central Network Slice Network Service)
- NFVO works with VNFM(s) to Instantiate VNFs
- NSSMF configures Central VNFs(C eMBB data)
- NSSMF(C) registers C NSSI (Capacity Available, Capacity Allocated )
- NSSMF => NSSMF(NE, UP)
- NSSMF(NE, UP) => SO( UP Network Slice Service (NE Parameters))
- NSSMF => NSMF(NE, RAN)
- NSSMF(NE, RAN) => SO (RAN Network Slice Service (NE Parameters)
- ...
- Resulting Network Service Deployment:
-
Gliffy |
---|
macroId | 64de5485-b7ac-406d-be81-f9c87eb4c00b |
---|
name | SliceSubnet-NS Deployment |
---|
pagePin | 1 |
---|
|
- NSSMF registers Nationwide NSSI (Capacity Available, Capacity Allocated ) with A&AI
- NSMF registers Nationwide eMBB Slice
- CSMF completes
Resulting Instance info:
Gliffy |
---|
macroId | 3cbd8d35-99ae-4a26-8db3-d224e12e2821 |
---|
name | eMBB Network Slice Instance |
---|
pagePin | 7 |
---|
|
New Slice Request (NE Enterprise):
- CSMF(NE Enterprise) => NSMF (NE Enterprise Service Profile)
- NSMF creates NE Enterprise Slice Profile
- NSMF => NSSMF (NE Enterprise Slice Profile)
- NSSMF Matches NE Enterprise Slice Profile to:
- NE (UP Network Slice Subnet Service, RAN Network Slice Subnet Service)
- C (Central Network Slice Subnet Service)
- NSSMF create Configuration data and Slice Profile for each instance:
- NE (UP, RAN) Slice Profiles
- C (Central) Slice Profile
- NSSMF Identifies existing Network Slice Subnet Instances with enough capacity for NE Enterprise Slice Profile:
- NE RAN NSSI
- NE UP NSSI
- C Central NSSI
- NSSMF => NSSMF (C)
- NSSMF(C) configures Central VNFs(C NE Enterprise data)
- NSSMF(C) update C NSSI (Capacity Available, Capacity Allocated )
- NSSMF => NSSMF(NE, UP)
- NSSMF(NE, UP) configures NE, UP VNFs(UP NE Enterprise data)
- NSSMF(NE, RAN) updates NE RAN NSSI (Capacity Available, Capacity Allocated )
- NSSMF => NSMF(NE, RAN)
- NSSMF(NE, UP) configures NE, UP VNFs(UP NE Enterprise data)
- NSSMF(NE, RAN) updates NE UP NSSI (Capacity Available, Capacity Allocated )
- NSSMF registers NE Enterprise NSSI (Capacity Available, Capacity Allocated ) with A&AI
- NSMF registers NE Enterprise Slice
- CSMF completes
Resulting Instance info:
Gliffy |
---|
macroId | ee395fbb-c168-4e11-9dd6-ea24470a10b2 |
---|
name | eMBB and NE Enterprise Network Slice |
---|
pagePin | 13 |
---|
|