- CSMF(eMBB Nationwide) => NSMF (eMBB Nationwide Service Profile)
- NSMF creates eMBB Nationwide Slice Profile
- NSMF => NSSMF (eMBB Nationwide Slice Profile)
- NSSMF Matches eMBB Slice Profile to:
- NE (UP Network Slice Subnet Service, RAN Network Slice Subnet Service)
- SE (UP Network Slice Subnet Service, RAN Network Slice Subnet Service)
- S (UP Network Slice Subnet Service, RAN Network Slice Subnet Service)
- C (Central Network Slice Subnet Service)
- N (UP Network Slice Subnet Service, RAN Network Slice Subnet Service)
- NW (UP Network Slice Subnet Service, RAN Network Slice Subnet Service)
- SW (UP Network Slice Subnet Service, RAN Network Slice Subnet Service)
- NSSMF create Configuration data and Slice Profile for each instance:
- NE (UP, RAN)
- SE (UP, RAN)
- S (UP, RAN)
- C (Central)
- N (UP, RAN)
- NW (UP, RAN)
- SW (UP, RAN)
- NSSMF Instantiate Network Slice Subnet Instances:
- NSSMF => NSSMF (C)
- NSSMF (C, Central) => SO (Central Network Slice Service (C Parameters)
- SO => NFVO (Central Network Slice Network Service)
- NFVO works with VNFM(s) to Instantiate VNFs
- NSSMF configures Central VNFs(C eMBB data)
- NSSMF(C) registers C NSSI (Capacity Available, Capacity Allocated )
- NSSMF => NSSMF(NE, UP)
- NSSMF(NE, UP) => SO( UP Network Slice Service (NE Parameters))
- NSSMF => NSMF(NE, RAN)
- NSSMF(NE, RAN) => SO (RAN Network Slice Service (NE Parameters)
- ...
- NSSMF => NSSMF (C)
- Resulting Network Service Deployment:
-
Gliffy macroId 64de5485-b7ac-406d-be81-f9c87eb4c00b name SliceSubnet-NS Deployment pagePin 1
-
- NSSMF registers Nationwide NSSI (Capacity Available, Capacity Allocated ) with A&AI
- NSMF registers Nationwide eMBB Slice
- CSMF completes
...
- CSMF(NE Enterprise) => NSMF (NE Enterprise Service Profile)
- NSMF creates NE Enterprise Slice Profile
- NSMF => NSSMF (NE Enterprise Slice Profile)
- NSSMF Matches NE Enterprise Slice Profile to:
- NE (UP Network Slice Subnet Service, RAN Network Slice Subnet Service)
- C (Central Network Slice Subnet Service)
- NSSMF create Configuration data and Slice Profile for each instance:
- NE (UP, RAN) Slice Profiles
- C (Central) Slice Profile
- NSSMF Iidentifies Identifies existing Network Slice Subnet Instances with enough capacity for NE Enterprise Slice Profile:
- NE RAN NSSI
- NE UP NSSI
- C Central NSSI
- NSSMF => NSSMF (C)
- NSSMF(C) configures Central VNFs(C NE Enterprise data)
- NSSMF(C) update C NSSI (Capacity Available, Capacity Allocated )
- NSSMF => NSSMF(NE, UP)
- NSSMF(NE, UP) configures NE, UP VNFs(UP NE Enterprise data)
- NSSMF(NE, RAN) updates NE RAN NSSI (Capacity Available, Capacity Allocated )
- NSSMF => NSMF(NE, RAN)
- NSSMF(NE, UP) configures NE, UP VNFs(UP NE Enterprise data)
- NSSMF(NE, RAN) updates NE UP NSSI (Capacity Available, Capacity Allocated )
- NSSMF registers NE Enterprise NSSI (Capacity Available, Capacity Allocated ) with A&AI
- NSMF registers NE Enterprise Slice
- CSMF completes
...