S.No. | Category | Test Case Description | Reference to main TC | Dependency | Tester | Status | ||||
---|---|---|---|---|---|---|---|---|---|---|
COM_01 | Service/template design | Successful design of CST and Service Profile Templates | 1 |
| ||||||
COM_02 | Service/template design | Successful design of NST (option 1 and option 2) | 2 |
| ||||||
COM_03 | Service instantiation (Option 1) | Service instantiation via CSMF Portal (UUI) for Option 1 (RAN NSSMF within ONAP) resulting in NST Selection request from SO towards OOF, and receiving the NST details in the callback from OOF. | 3 | COM_02 |
| |||||
COM_04 | Service |
instantiation (Option 1) | After NST selection, NSMF (SO) |
fetches sub-net capabilities for the 3 constituent sub-nets (RAN, Core and Transport) for Option 1. | 3 | COM_03 |
| |||||
COM_05 | Service |
instantiation (Option 1) | NSMF (SO) to trigger OOF for NSI selection, resulting in OOF providing Slice Profiles (in callback API) for new NSI creation (Option 1). | 3 | COM_04 |
| |||||
COM_06 |
Service instantiation (Option 1) | NSMF Portal (UUI) provides endpoints for RAN and Core sub-nets | 3 | COM_05 |
| ||||||
COM_07 | Service instantiation (Option 1) | NSMF (SO) triggers RAN NSSMF with allocateNSSI operation via the NSSMF adaptor, and RAN NSSI is allocated successfully. | 3 | COM_06 |
| |||||
COM_08 | Service instantiation (Option 1) | NSMF (SO) triggers Core NSSMF with allocateNSSI operation via the NSSMF adaptor, and |
Core NSSI is allocated successfully. | 3 | COM_06 |
| |||||
COM_09 | Service instantiation (Option 1) | NSMF (SO) triggers TN NSSMF with allocateNSSI operation via the NSSMF adaptor along with the RAN & Core endpoint info, and TN NSSI is allocated successfully. | 3 | COM_ |
06 |
|
2. RAN Slicing