Note |
---|
ODL is operated as a cluster. The configuration settings are the same for each cluster node. |
Table of Contents |
---|
Image
ONAP SDN-R is running in a docker container using ONAP/SDN-C image "onap/sdnc". These images are stored in ONAP Nexus sdnc image.
The image contains Opendaylight in a standard configuration.
Parameter | Content | Description |
---|---|---|
ODL_HOME | /opt/opendaylight | Root location of ODL Karaf directory structure |
JAVA_HOME | Pointing to the java version, used by ODL | |
SDNRWT | true|false | Set true to activate sdnr wt featureset. Set this during container start |
Configuration
Configuration of sdnr wireless transport parameters is in the file $ODL_HOME/etc/devicemanager.properties. The file contains sections for services of devicemanager.
If SDN-R WT is starting
- and the file exists, the configuration is used.
- if it does not exist it is will be created with the default parameters.
...
...
Below an example of the content.
Code Block | ||
---|---|---|
| ||
[toggleAlarmFilter]
taEnabled=true
taDelay=3000
[es]
esCluster=sdnr
esArchiveCheckIntervalSeconds=0
esArchiveLifetimeSeconds=2592000
[dcae]
dcaeUrl=off
dcaeUserCredentials=admin:admin
dcaeHeartbeatPeriodSeconds=120
[aai]
aaiUrl=off
aaiUserCredentials=
aaiHeaders=["X-TransactionId: 9999"]
aaiDeleteOnMountpointRemove=false
aaiTrustAllCerts=false
aaiPropertiesFile=
aaiApiVersion=aai/v13
aaiApplicationId=SDNR
aaiClientConnectionTimeout=30000
aaiPcks12ClientCertFile=
aaiPcks12ClientCertPassphrase=
[pm]
pmEnabled=true
pmCluster=sdnr
[devicemonitor]
SeverityconnectionLossOAM=Major
SeverityconnectionLossMediator=Major
SeverityconnectionLossNeOAM=Major |
Sections
toggleAlarmFilter
Configure toggle alarm filter.
taEnabled=true taDelay=3000
Parameter | Values | Default | Unit | Description |
---|---|---|---|---|
taEnabled | true, false | false | Enable or disable this service | |
taDelay | number | milliseconds | Integration time to take over the new alarm status |
devicemonitor
Configure alarm severity of related alarms, generated by Device Monitor.
Syntax: Parameter=Value
Example: SeverityconnectionLossOAM=Major
Values | Default | Unit | Description | |
---|---|---|---|---|
SeverityconnectionLossOAM | NonAlarmed, Warning, Minor, Major, Critical | Major | SDN-Controller <> Mediator Mountpoint monitoring. Indicates a not connected mounpoint | |
SeverityconnectionLossMediator | NonAlarmed, Warning, Minor, Major, Critical | Major | SDN-Controller <> NetworkElement Device monitoring. No LTPs provided | |
SeverityconnectionLossNeOAM | NonAlarmed, Warning, Minor, Major, Critical | Major | SDN-Controller <> NetworkElement Device monitoring. SSH Connetion, Core model not answering |