Project Name | OOM | Notes | |||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Health Check | Pass | As of status on 04/30 on Integration-OOM-Staging-Daily | |||||||||||||||||||||||||||||||
Data flows for all use case | VES data reception (VNF to VES simulated) | Pass | DCAE-VNF_VES_TCA.txt | ||||||||||||||||||||||||||||||
VES ↔ TCA , via DMaaP | Pass | See above attachment | |||||||||||||||||||||||||||||||
TCA ↔ Policy, via DMaaP | Pass | See above attachement | |||||||||||||||||||||||||||||||
DCAE (TCA) ↔ AAI, via API | Pass | See above attachement | |||||||||||||||||||||||||||||||
DCAE (VES) ↔ Holmes (track metrics data), via DMaaP | Pass | ||||||||||||||||||||||||||||||||
Control flow for supporting CLAMP | DCAE↔ CLAMP (CLAMP trigger blueprint deployment) , via DCAE Deployment Handler API | In-Progress | Blocked by 05/06 - Identified few issues on Policy in recent test (
SDC distribution issue to CLAMP/Policy
| ||||||||||||||||||||||||||||||
SDC↔ DCAE (blueprint distribution from SDC to DCAE Service Change Handler) | Pass | ||||||||||||||||||||||||||||||||
DCAE (Policy Handler) ↔ Policy, via API | In-ProgressBlocked by | 05/06 - Connection validated; identified few issues on Policy in recent test (
SDC distribution issue to CLAMP/Policy
|
...
ONAP Bootstrapped services (non-usecase specific) | ||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
PNF Reg Flows | VES ↔ PRH, via DMaaP | In-Progress/Works fine | Needs Passed | 05/06 - logs_robot_windriver_pnf_registrate.zip Dependent on
| ||||||||||||||||||||||||||||
PRH ↔ AAI, via API | Passed | In-Progress/Works fine | Needs 05/06 - See above attachment Dependent on
| |||||||||||||||||||||||||||||
PRH ↔ SO, via DMaap | In-Progress /BlockedNeeds from DCAE team (can be Passed based on SO team's test) | Note: SO team confirmed (during TSC meeting) that this test was validated/successful on their side. 05/06 - Requires Portal being up - Wind river Portal page not accessible; also at Nokia's lab Portal page not working. Internal 500 server error. Dependent on
| ||||||||||||||||||||||||||||||
HV-VES | WTP:GPB message ↔ HV-VES (tcp/socket) | Passed | ||||||||||||||||||||||||||||||
HV-VES ↔ DMAAP/kafka | Passed |
...