- Where this information comes from? Ext-API when ordering a service? CL event? What is the API used?
- Is the piece really needed to be in A&AI? (for example if only SDN-C uses it for resource controlling, then it could just come as input to its NBI and stored in MD-SAL)
- Which component is going to use it from A&AI?
BBS Properties |
---|
Per HSIA CFS Service Instance | Input Source |
---|
ONAP Components that must fetch the value from A&AI |
---|
Does it really need A&AI storage? | A&AI Metaname (for Metadata) | |||
---|---|---|---|---|
RG MAC Address | Service Order via Ext API It also comes in the CPE Authentication Event | bbs-event-processor DCAE microservice (it fetches existing value from A&AI to compare it with the new value coming from PNF CPE authentication event in order to deduce if there is any mismatch) | Yes, as metadata of CFS service instance | rgw-mac-address |
Service Type | Service Order via Ext API | |||
Access ID | PNF registration event | |||
Upstream Speed | Service Order via Ext API | |||
Downstream Speed | Service Order via Ext API | |||
OLT Name | PNF registration event (extracted from attachment point) | |||
OLT PON port | PNF registration event (extracted from attachment point) | |||
OLT PON slot | PNF registration event (extracted from attachment point) | |||
CVLAN | PNF registration event | |||
SVLAN | PNF registration event | |||
Expected ONT ID | ||||
CPE Manufacturer | Onboarded to SDC for PNF | Yes, as property of PNF object | Not Applicable | |
CPE Model | Onboarded to SDC for PNF | Yes, as property of PNF object | Not Applicable | |
CPE Equipment Type | Onboarded to SDC for PNF | Yes, as property of PNF object | Not Applicable | |
CPE Serial Number | Yes, as property of PNF object | Not Applicable | ||
CPE SW Version | It comes in the CPE Authentication Event | Yes, as property of PNF object | Not Applicable | |
Attachment Point (Not a real BBS modeling property, since its constituent parts are captured in other model properties) | PNF registration event | bbs-event-processor DCAE microservice (it fetches existing value from A&AI to compare it with the new value coming from PNF re-registration event in order to deduce if it is a true relocation) | Yes, as value of link-name property of a logical-link bridged to the PNF object | Not Applicable |
ONT NNI Port | ||||
OLT NNI Slot | ||||
OLT NNI Port |