Beijing Specific Tests

Test No.

Category

(Stability, Resiliency, ConfigScaleOut, Scalability)

Description

Status

(Not Started, In-Progress, Pass, Fail)

Notes
1StabilityExecute Restart Test for 72 hour periodPassTested against Amsterdam code due to defect APPC-658 which prevents DMaaP messages from being received or sent.  Test results and notes can be found at:  ONAP APPC 72 Hour Stability Test Results
2StabilityExecute Rebuild Test for 72 hour periodPassTested against Amsterdam code due to defect APPC-658 which prevents DMaaP messages from being received or sent.  Test results and notes can be found at:  ONAP APPC 72 Hour Stability Test Results
3StabilityExecute Start Test for 72 hour periodPassTested against Amsterdam code due to defect APPC-658 which prevents DMaaP messages from being received or sent.  Test results and notes can be found at:  ONAP APPC 72 Hour Stability Test Results
4StabilityExecute Stop Test for 72 hour periodPassTested against Amsterdam code due to defect APPC-658 which prevents DMaaP messages from being received or sent.  Test results and notes can be found at:  ONAP APPC 72 Hour Stability Test Results
5Resiliency

Verify that loss of one MYSQL slave instance does not impact DB availability.

Pass (on Carbon ODL)

Pass (on Nitrogen ODL)

Since MariaDB and Galera support is not being introduced in this release, this test involves terminating the one MySQL instance and verifying that Kubernetes brings the instance back up successfully.
6Resiliency

Verify that loss of one APPC controller instance does not impact application availability

Pass (on Carbon ODL)

Pass (on Nitrogen ODL)

Loss of one APPC controller instance does not impact application availability.
7

Scalability

Scale (up or down) MySQL dynamically.FailDynamic scaling for the database is scheduled to be supported with the introduction of MariaDB and Galera in a future release.
8

Scalability

Scale (up or down) APPC controller dynamically.

Pass with issue (on Carbon ODL)

Testing in Progress Pass with issue (on Nitrogen ODL)

The APPC controller can be dynamically scaled, preserving the correct ODL configuration; however, the ODL cluster is not configured properly after the scaling operation. Based on this issue, it is recommended to use static scaling such that the cluster size is set appropriately at the time of installation to ensure a properly functioning ODL cluster.
9ConfigScaleOut






















Regression Tests

...