R2+ AttributesQualifierCardinalityContentDescriptionProducerConsumer
uuidM1String(Identifier)Identifier of Fowarding ConstructSDCSDC/UUI/SDNC
nameO1StringHuman readable name for FCSDCSDC/UUI/SDNC
versionM1StringIdentify the version of FCSDCSDC/UUI/SDNC
descriptionO1StringAdditional infomation for FC descriptionSDCSDC/UUI/SDNC
topologyM1StringFC topology, valid values for now: ['hub-spoke', 'fullmesh', 'p2p']SDCSDC/UUI/SDNC
tenantO1StringTenant information for the FCSDCSDC/UUI/SDNC
creatorO1StringThe creator of the FCSDCSDC/UUI/SDNC
endPointIdendPointDIdM1..NStringReferences the end points of FC. Each end point is described by FC Point.SDCSDC/UUI/SDNC
subFcIdsubFcDIdM0..NStringReferences the lower level FCs which are internal construction of an FC. Lower level FC could belong to different domain.SDCSDC/UUI/SDNC
fcRouteIdfcRouteDIdM0..NStringReferences the fc route which describes the routing relationships within FC.SDCSDC/UUI/SDNC
configurationIdconfigurationDIdM0..NStringReferences the specify configurationSDCSDC/UUI/SDNC

...

R2+ AttributesQualifierCardinalityContentDescriptionProducerConsumer
uuidM1String(Identifier)Identifier of Fowarding Construct PointSDCSDC/UUI/SDNC
nameO1StringHuman readable name for FC PointSDCSDC/UUI/SDNC
versionM1StringIdentify the version of FC PointSDCSDC/UUI/SDNC
descriptionO1StringAdditional infomation for FC Point descriptionSDCSDC/UUI/SDNC
interfaceO1StringThe associated interfaceSDCSDC/UUI/SDNC
addressO1StringIp address or mac address of the associated interfaceSDCSDC/UUI/SDNC
hub-spoke-roleO1StringRole of the FC Point while the related FC has hub-spoke topology.SDCSDC/UUI/SDNC
nodeIdnodeDIdM0..1StringReferences the node which the FC Point host on.SDCSDC/UUI/SDNC
configurationIdconfigurationDIdM0..NStringReferences the specify configurationSDCSDC/UUI/SDNC

...

R2+ AttributesQualifierCardinalityContentDescriptionProducerConsumer
uuidM1String(Identifier)Identifier of NodeSDCSDC/UUI/SDNC
nameO1StringHuman readable name for NodeSDCSDC/UUI/SDNC
versionM1StringIdentify the version of NodeSDCSDC/UUI/SDNC
descriptionO1StringAdditional infomation for Node descriptionSDCSDC/UUI/SDNC
addressO1StringIp address or mac address or geograhic address of the nodeSDCSDC/UUI/SDNC
vendorO1StringVendor information of the nodeSDCSDC/UUI/SDNC
parentNodeIdparentNodeDIdM0..1StringReferences the parent node which the node host on.SDCSDC/UUI/SDNC
configurationIdconfigurationDIdM0..NStringReferences the specify configurationSDCSDC/UUI/SDNC

...

R2+ AttributesQualifierCardinalityContentDescriptionProducerConsumer
uuidM1String(Identifier)Identifier of FC RouteSDCSDC/UUI/SDNC
nameO1StringHuman readable name for FC RouteSDCSDC/UUI/SDNC
versionM1StringIdentify the version of FC RouteSDCSDC/UUI/SDNC
descriptionO1StringAdditional infomation for FC Route descriptionSDCSDC/UUI/SDNC
xcIdxcDIdM0..NStringReferences the related XC which describes the exchange relationship within network elementSDCSDC/UUI/SDNC
lcIdlcDIdM0..NStringReferences the related Link Connection which describes the connection between network elementsSDCSDC/UUI/SDNC
configurationIdconfigurationDIdM0..NStringReferences the specify configurationSDCSDC/UUI/SDNC

...

R2+ AttributesQualifierCardinalityContentDescriptionProducerConsumer
uuidM1String(Identifier)Identifier of Link ConnectionSDCSDC/UUI/SDNC
nameO1StringHuman readable name for Link ConnectionSDCSDC/UUI/SDNC
versionM1StringIdentify the version of Link ConnectionSDCSDC/UUI/SDNC
descriptionO1StringAdditional infomation for Link Connection descriptionSDCSDC/UUI/SDNC
topologyM1StringLink connection topology, valid values for now: ['hub-spoke', 'fullmesh', 'p2p']SDCSDC/UUI/SDNC
fcIdfcDIdM0..1StringReferences the FC of the service layer which link connection depends onSDCSDC/UUI/SDNC
endPointIdendPointDIdM0..NStringReferences the end points which the link connectsSDCSDC/UUI/SDNC
configurationIdconfigurationDIdM0..NStringReferences the specify configurationSDCSDC/UUI/SDNC

...

R2+ AttributesQualifierCardinalityContentDescriptionProducerConsumer
uuidM1String(Identifier)Identifier of Exchange ConnectionSDCSDC/UUI/SDNC
nameO1StringHuman readable name for Exchange ConnectionSDCSDC/UUI/SDNC
versionM1StringIdentify the version of Exchange ConnectionSDCSDC/UUI/SDNC
descriptionO1StringAdditional infomation for Exchange Connection descriptionSDCSDC/UUI/SDNC
endPortIdendPortDIdM2..NStringReferences the XC Point which XC connectsSDCSDC/UUI/SDNC
neIdneDIdM0..1StringReferences the node which XC hosts onSDCSDC/UUI/SDNC
configurationIdconfigurationDIdM0..NStringReferences the specify configurationSDCSDC/UUI/SDNC

...

R2+ AttributesQualifierCardinalityContentDescriptionProducerConsumer
uuidM1String(Identifier)Identifier of XC PointSDCSDC/UUI/SDNC
nameO1StringHuman readable name for XC PointSDCSDC/UUI/SDNC
versionM1StringIdentify the version of XC PointSDCSDC/UUI/SDNC
descriptionO1StringAdditional infomation for XC Point descriptionSDCSDC/UUI/SDNC
hub-spoke-roleO1StringRole of the XC Point while the related LC has hub-spoke topologySDCSDC/UUI/SDNC
interfaceO1StringThe associated interfaceSDCSDC/UUI/SDNC
peerIdO1StringIdentifier of peerSDCSDC/UUI/SDNC
nodeIdnodeDIdM0..1StringReferences the node which XC Point hosts onSDCSDC/UUI/SDNC
configurationIdconfigurationDIdM0..NStringReferences the specify configurationSDCSDC/UUI/SDNC

...

R2+ AttributesQualifierCardinalityContentDescriptionProducerConsumer
uuidM1String(Identifier)Identifier of configurationSDCSDC/UUI/SDNC
nameO1StringHuman readable name for configurationSDCSDC/UUI/SDNC
versionM1StringIdentify the version of configurationSDCSDC/UUI/SDNC
descriptionO1StringAdditional infomation for configuration descriptionSDCSDC/UUI/SDNC
parasM0..NStringSpecify parameters of the configurationSDCSDC/UUI/SDNC
deploy-orderO1integerDeploy order of the configuration, smaller number means deploy firstSDCSDC/UUI/SDNC
subConfigurationIdsubConfigurationDIdM0..NStringReferences the sub configurationSDCSDC/UUI/SDNC

...