Then you have to deploy the rule into Holmes . by calling:
Code Block |
---|
|
curl -X PUT -H 'Content-Type: application/json' -d @holmesrule http://10.96.33.33/api/holmes-rule-mgmt/v1/rule |
The rule is saved into a file named "holmesrule" and it attached here.DMAAP message for alarm from EMS driver
Info |
---|
If there are modifications performed by yourself, please update the contents of the holmesrule file first. |
If you want to update an existing rule, you have to add a field named "ruleid" into the holmesrule file using the real id returned by the API called above and then call:
Code Block |
---|
|
curl -X POST-H 'Content-Type: application/json' -d @holmesrule http://10.96.33.33/api/holmes-rule-mgmt/v1/rule |
For more information, please refer to Rule Management.
Theoretically, after the configurations are finished, when you push the fault data on to the topic named "unauthenticated.SEC_FAULT_OUTPUT" of DMaaP, the data will be fetched and processed by Holmes and then push back to the topic named "unauthenticated.DCAE_CL_OUTPUT" of DMaaP. To support the correlation analysis, A&AI have to be ready with certain resource data in it and registered to MSB.
Sample Data
DMaaP Message for Alarms from the EMS Driver
Code Block |
---|
|
["{\"VESversion\":\"v5\",\"event\":{\"commonEventHeader\":{\"sourceId\":\"VNF_194.15.13.138\",\"startEpochMicrosec\":1501518702,\"eventId\":\"1501489595451\",\"nfcNamingCode\":\"\",\"reportingEntityId\":\"0000ZTHX1\",\"internalHeaderFields\":{\"collectorTimeStamp\":\"Fri, 10 20 2017 01:49:27 GMT\"},\"eventType\":\"applicationVnf\",\"priority\":\"High\",\"version\":3,\"reportingEntityName\":\"0000ZTHX1\",\"sequence\":960,\"domain\":\"fault\",\"lastEpochMicrosec\":1501518702,\"eventName\":\"Slave MPU is offline\",\"sourceName\":\"VNF_194.15.13.138\",\"nfNamingCode\":\"\"},\"faultFields\":{\"eventSeverity\":\"CRITICAL\",\"alarmCondition\":\"The slave MPU board is offline or abnormal\",\"faultFieldsVersion\":2,\"eventCategory\":\"equipmentAlarm\",\"specificProblem\":\"The slave MPU board is offline or abnormal\",\"alarmInterfaceA\":\"VNF_194.15.13.138\",\"alarmAdditionalInformation\":[{\"name\":\"specificProblemID\",\"value\":\"315\"},{\"name\":\"objectUID\",\"value\":\"0000ZTHX1PGWGJI6V1\"},{\"name\":\"locationInfo\",\"value\":\"MPU_22_20_0\"},{\"name\":\"addInfo\",\"value\":\"Aid:17;AlarmCode:110010;AlarmReasonCode:110010;Remark:\\\"DeployUnit=22,Node=21,SubNode=0\\\";\"}],\"eventSourceType\":\"PgwFunction\",\"vfStatus\":\"Active\"}}}"] |
Above is the literals returned by DMaaP. Hence some symbols are escaped. If you want to push the data onto DMaaP, please use the data contained in VES.
DMaaP Message for Control Loop Events from Holmes
Code Block |
---|
|
{
"target": "vserver.vserver-id",
"target_type": "VM",
"AAI": {
"vserver.in-maint": true,
"vserver.is-closed-loop-disabled": true,
"vserver.prov-status": "example-prov-status-val-2",
"vserver.resource-version": "1504912891060"
"vserver.vserver-id": "example-vserver-id-val-2",
"vserver.vserver-name": "example-vserver-name-val-2",
"vserver.vserver-name2": "example-vserver-name2-val-2"
"vserver.vserver-selflink": "example-vserver-selflink-val-2"
},
"closedLoopAlarmStart": 1484855291527925,
"closedLoopEventStatus": "ONSET",
"closedLoopControlName": "VoLTE",
"version": "1.0.2",
"requestID": "8c1b8bd8-06f7-493f-8ed7-daaa4cc481bc",
"from": "DCAE"
} |