Example of alarm event sent from VFC
{
"event":{
"commonEventHeader":{
"version": 3.0,
"eventName": "Slave MPU is offline",
"domain": "fault",
"eventId": "1501489595451",
"eventType": "applicationVnf",
"nfcNamingCode": "",
"nfNamingCode": "",
"sourceId": "VNF_194.15.13.138",
"sourceName": "VNF_194.15.13.138",
"reportingEntityId": "0000ZTHX1",
"reportingEntityName": "0000ZTHX1",
"priority": "High",
"startEpochMicrosec": 1501518702,
"lastEpochMicrosec": 1501518702,
"sequence": 960
},
"faultFields":{
"faultFieldsVersion": 2.0,
"eventSeverity": "CRITICAL",
"eventSourceType": "PgwFunction",
"eventCategory": "equipmentAlarm",
"alarmCondition": "The slave MPU board is offline or abnormal",
"specificProblem": "The slave MPU board is offline or abnormal",
"vfStatus": "Active",
"alarmInterfaceA": "VNF_194.15.13.138",
"alarmAdditionalInformation": [{
"name":"specificProblemID",
"value": "315"
}, {
"name":"objectUID",
"value":"0000ZTHX1PGWGJI6V1"
}, {
"name":"locationInfo",
"value":"MPU_22_20_0"
}, {
"name":"addInfo",
"value":"Aid:17;AlarmCode:110010;AlarmReasonCode:110010;Remark:\"DeployUnit=22,Node=21,SubNode=0\";"
}]
}
}
...
VFC: sampleves
Curl command to send REST request to VES
...