Test Case IdV00015
Test Case NameVoLTE Auto-healing
DescriptionThis test covers the closed loop with alarm correlation and auto-healing
ReleaseAmsterdam
Preconditions
  1. VoLTE service has been instantiated
  2. VoLTE closed loop has been configured and started
  3. SPGW VNF supports event generation
  4. VNF guest OS supports event generation
  5. MultiVIM supports event collection from guest OS and event forwarding
Testing Steps
  1. Use Robot test script to Manually shutdown standby MPU VM inside SPGW VNF. This should trigger the VNF and VIM to generate alarms
Expected Results
  1. EMS collects standby MPU offline event from SPGW VNF and sends the event to VFC
  2. MultiVIM doesn't receive heartbeat event from standby MPU guest OS for a period of time and triggers alarm which is sent to DCAE VES collector
  3. Holmes receives MPU offline events
  4. Holmes receives MPU guest OS heartbeat missing events
  5. Holmes does correlation of the two types of events and generate one signature event and sends it to Policy
  6. Policy triggers provisional policy and healing action is sent to VFC
  7. VFC uses SVNFM driver to heal standby MPU VM
  8. Standby MPU is healed
  9. Clear event is sent from SPGW VNF about standby MPU back online
  10. Heartbeat from standby MPU VM is received by MultiVIM and clear event is sent by MultiVIM about heartbeat recovery
  11. Holmes does the event correlation and sends Clear signature event to Policy
  12. Policy stops the healing action
Actual Results
Conclusion (Pass/Fail)