We use the similar lab infrastructure recommended by OPNFV project. 

...

The lab specification section provides information for recommended hardware and network configuration.

...

Overview

A ONAP lab compliant test-bed provides:

  • One CentOS 7 jump server on which the installer runs
  • More then one POD should be delivered depends on the usage scenarios.
  • A configured network topology allowing for LOM(Lights-out Management), Admin, Public, Private, and/or Storage Networks if needed.
  • Remote access through VPN or other approach provided by individual labs
  • Security through a firewall

...

Hardware

Servers 

CPU:

    • Intel Xeon E5-2658v3 Series or newer, with 12 cores and 24 hyper-threads

...

Single power supply is acceptable(redundant power not required/nice to have)

...

Network Hardware

  • TOR Switch
  • Router
  • others

Networking

    • 48 Port TOR Switch

    • NICs - Combination of 1GE and 10GE based on network topology options

    • Connectivity for each data/control network is through a separate NIC port or a shared port. Separate port simplifies switch management however requires more NICs on the server and also more switch ports

    • BMC (Baseboard Management Controller) for lights-out management network using IPMI (Intelligent Platform Management Interface)

...

    • Option I: 4x1G Control, 2x10G Data, 48 Port Switch
      • 1 x 1G for IPMI Management
      • 1 x 1G for Admin/PXE boot
      • 1 x 1G for control-plane connectivity
      • 1 x 1G for storage
      • 2 x 10G for data network (redundancy, NIC bonding)
    • Option III: 2x1G Control, 1x10G Data(redundancy nice to have), 1x10G Control or Storage(if needed, redundancy nice to have), 48 Port Switch
      • Data NIC used for VNF traffic
      • 1 x 1G for IPMI mangement
      • 1 x 1G for Admin/PXE boot
      • 1 x 10G for control-plane connectivity/storage(if needed,  control plane and storage segmented through VLANs)
      • 1 x 10G for data network

...

Lights-out management network requirements:

    • Out-of-band management for power on/off/reset and bare-metal provisioning
    • Access to server is through a lights-out-management tool and/or a serial console
    • Refer to applicable light-out management information from server manufacturer, such as ...
      • Intel lights-out RMM
      • HP lights-out ILO
      • CISCO lights-out UCS
      • Dell iDRAC

...