Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

    • Out-of-band management for power on/off/reset and bare-metal provisioning
    • Access to server is through a lights-out-management tool and/or a serial console
    • Refer to applicable light-out management information from server manufacturer, such as ...
      • Intel lights-out RMM
      • HP lights-out ILO
      • CISCO lights-out UCS
      • Dell iDRAC


Pod

ONAP Open labs Labs are collections of dedicated hardware, generally partitioned into pods with servers. Pods can be used for different testings like development, CI/CD, ONAP platform testing, or E2E testing.

In the following table, we define 3 types of Pod based on the resource usage assumption. Please note in lab and real deployment scenarios, resource can be over subscribed depending on workload. Also we assume that ONAP platform will be deployed in a separate Pod pod from VNFs. 


Type of PodUse Case

Total Memory(GB)

for Compute Nodes

Total VCPU

for Compute Nodes

Total Storage

for Compute Nodes

Number of Control NodesNumber of Compute Nodes
LargeVoLTE900GB1804T3>=2
MediumONAP Platform or vCPE200GB1002T3>=2
SmallDevelopment or vFW/vDNS demo apps40GB241T1>=1


Using the above large pod requirement, we can build a hypothetical pod with servers listed in the following table:

...