Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

  1. The DCAE Controller is instantiated from an OpenECOMP Heat template.
  2. The DCAE Controller instantiates the rest of the DCAE components, including both infrastructure and service/application components.
  3. The DCAE Controller configures service/application components with static configurations, configuration policies fetched at run-time (for example data processing configurations or alert configurations), and any DMaap topics required for communication.

Image RemovedImage Added

Figure 2. DCAE configuration flow (Control plane)

...

  1. VNFs use REST calls to push measurement data to the DCAE VES collector.
  2. The VES collector validates, filters, and packages the received measurement data, and publishes the data to the "measurement data" topic of DMaaP.
  3. The analytics application receives measurement data from the DMaaP "measurement data" topic.
  4. The analytics application analyzes measurement data, and if alert conditions (defined by the alert policy that was installed by the DCAE Controller) are met, publishes an alert event to the DMaaP "event data" topic. 
  5. Other OpenECOMP components, for example the Policy or MSO subsystems, receive alert events from the DMaaP "event data" topic and react accordingly.

...

Image Added

Figure 3. DCAE data flow (Data plane)